Product Name: 2000-MTC Master Time/Program Clock
Product Description
User programmable
Eight program schedules
64 time events per schedule
Automatic adjustment for daylight savings time
Four-digit time/event display
12-hour AM/PM indication
10 year battery backup
Surface, semi-flush or rack mountable
The Edwards Catalog 2000-MTC Master Time/Program Clock is a compact, microprocessor controlled clock capable of maintaining system time for Edwards digital clocks and many third party secondary clocks. The unit consists of a display unit and power/relay that can be assembled in a surface mount configuration. The display unit has a digital display that shows the date and time and provides programming menus to guide the user through programming and operating modes. A 12 button key pad is used to manually enter commands and programming instructions. The front panel LEDs indicate control relay status. The 2000-MTC uses the Edwards 2000-DCT-REL for timing control.
All wiring to AC power and secondary equipment (clocks, bells, and zone controls) connect to terminal blocks within the power/relay unit backbox using quick connects supplied with the master clock.
Time synchronization is derived from the AC line frequency. The clock automatically detects the selection of 50 or 60 Hz. During power failures, accurate time is maintained by a quartz crystal supported by lithium battery backup. When AC power is restored, the clock's microprocessor calculates the amount of time lost and resynchronizes the secondary clocks. In addition to the hourly and periodic synchronization of secondary clocks, the master clock can automatically adjust for daylight savings time.
The master clock has eight signal circuits, four of which can be designated for clock synchronization. Circuits not used for synchronization can be manually operated by the key pad, or automatically, according to the active schedule. Each relay circuit can be wired to a separate path to control signal devices in specific areas of the facility. The clock can be programmed with up to eight schedules, each containing up to 64 multi-functional events. Schedules can be simultaneously active, providing up to 512 multi-functional events. Each of the 64 events (per schedule) include the hour, minutes, days of the week, desired circuits, and duration of activation. Each event can be set for 1 to 99 seconds or, using start and stop times, separated by 23 hours and 59 minutes. A table of sixteen holidays can be created so that normal schedules can be easily modified and automatically restored at the end of each holiday. The clock also maintains a schedule of up to 16 schedule-change dates to accommodate the automatic activation of seasonal schedule changes. The master clock supports four modes of operation: clock, program, run, and sleep. Clock mode displays the time and date and scans the keypad for user input and the communication ports for external data. Program mode interacts with the user during manual programming procedures, presenting the menus and saving user instructions in protected memory. Run mode executes whenever AC power is applied to the master clock. In run mode, secondary clocks are synchronized and user-programmed bell/zone schedules are carried out. If AC power to the clock is interrupted, the clock enters sleep mode, in which programmed instructions and setup parameters are preserved and only the internal real-time clock remains active to maintain the date and time. The master clock can be programmed from the front panel or from a computer using the supplied software.
Company Details
Edwards Signaling & security systems manufacturers a complete line of fire alarm, audible and visual signals for industrial application, commercial applications, and security applications. Edwards Products include: Edwards, edwards signaling,... more
| More Products of this Company: |
-8322 and B-8323 Series, 100SB Series PathfinderTM Heavy Duty Rotating Light, 102 Series Triliptical Stackable Status Indicator, 105 Series AdaptaBeacon Adverse Location Signal, 1064 and 1065 Series Strap Mounted Buzzer, 1066 Series High Voltage Buzzer, 115 Series Miniature LungenTM Buzzer, 116DEXMRINH-GW Series AdaptaBeacon Explosionproof Rotating Lights, 116DEXMSINH-GW Series AdaptaBeacon Explosionproof Steady-On Lights, 116DEXMST-FJ Series AdaptaBeacon Explosionproof Strobes, 116DEXSTC-FJ AdaptaBeacon Explosionproof Strobe, 116EXMRIN Series AdaptaBeacon Explosionproof Rotating Lights, 116EXMST*-N5 Series AdaptaBeacon Explosionproof Strobes, 116EXST*-EK Series AdaptaBeacon Explosionproof Strobes, 118 and 123A Series Midi Vibrating Horns, 13 Series General Purpose Miniature Bells, 147-1 and 149-1 Push Button Plates, 147-10 Mounting Plate, 15 Series Miniature LungenTM Buzzer, 150 and 151 Series Door Openers, 1500 Series Door Holder Extension Rods, 152 Series Door Opener, 154 Series Door Opener, 156G Series General Purpose Bells, 17500, 177 and 178 Series Door Openers, 1786 Series Weatherproof Push Buttons, 180 and 181 Series Door Openers, 1884A 15 Inch Analog Clocks, 1885A 12 Inch Analog Clocks, 1886 & 1887 Series 8 Inch & 12 Inch Analog Clocks, 1888, 1889, 1899 & 2476B Series Clock Accesssories, 1893 & 1894 Series LCD Digital Clocks, 1900MS12-24 LED Wall Clock, 2000-DCT System Digital Clock Timer/Controller, 2000-SC Series System Clocks, 236 Door Trip, 5530M / 5530MV Series Adaptatone Millennium Multiple Tone Signal Single OutputRS485 Activation, 5560M Series Millennium Mini-MiTM Voice & Tone Generator, 590 Series, 593 Transformer Mounting Plate, 6000-AMFMCAS, 6000-AMFMCAS-PA, 6000-AMP Series, 6000-DM, 6000-MP Series, 6000-MTG, 6000-RS-25/70 Series, 6000-S-8-25/70 Series, 6536-G5 Horn/Strobe, 6537 Pull Cord Station, 6538-G5 Call for Assistance KitMeets ADA requirements, 7005-G5 Hotel Room Annunciator KitAudible and Visual Signals, 7007B-N5 Buzzer / Strobe, 7008B-N5 Call For Assistance KitMeets ADA requirements, 7035 Nurse Call AnnunciatorsAudible and Visual Signals, 7035 Nurse Call AnnunciatorsAudible and Visual Signals, 7302 Series Bedside Stations, 7603 & 7613 Series Wall Stations, 7615 Calling Cord Security Clamp, 7620 Pendant Push ButtonLocking, Momentary Contact, 7633 Series Corridor Dome StationsAudible and visual signals,internal buzzer, 7641 Series Corridor Dome Stations, 7675- 7676- 7685 and 7686 Series Calling Cord Sets, 7930 & 7930L Wall Stations, 851 Pendant Push Button, 88 Series Heavy Duty Power Transformers, 92-R5 Series AdaptaBeacon Light Duty Strobe, 9704 Series Latching Annunciator, A1 Series Klaxon Motor Driven Horn Weatherproof, Airchime Air Horn Control Valves, Airchime Steam Whistle Valves, B-8313 Series, B-8315 and B-8316 Series, B-ER-2000 Series, B-ERW-2100, B-KBH-5040-N5, B-KBP-5060-N5, B-KHD-1000-PP, B-KHE-1000-PP, B-KHP-8010-N5, B-KHS-1000-PP, C Series, CO2-5 / CO2-10 / PF-1625 Airchime Air Horns, E-FS Series FireShield Fire Alarm Control Panel Conventional 1, 3, 5 & 10 Zones, EBPS6 & EBPS10 Remote Booster Power Supplies Expands Power to NACs, Edwards Warning Siren Accessories, EG1* Series Genesis® Horns, Strobes & Horn/Strobes, EG1M Series Signal Master Synchronization ModuleMeets UL 1971 synchronization requirements, EGC-S Series Genesis Ceiling SpeakerField Configurable, EGC-SVM Series Genesis Ceiling Speaker/StrobesField Configurable, EGC-VM Series Genesis Ceiling StrobesField Configurable, EWS-11 Series, EWS-V1 Series OMNI-Directional Edwards Warning Siren107 dB, Skirted Horn Design, EWS-V2 Series, EWS-V3 & EWS-V10 Series, EWS-V4 Series, EWS-V6 & EWS-V9 Series, EWS-V7 Series, EWS-V8-3, K Series, KH Series Klaxon Manual Horn Unique Klaxon Sound, KM Series, KMJ Series, MC1 Series LED 1 Line Message CentersUp to 51 Characters, MC2 Series LED 2 Line Message CentersUp to 120 Characters, MC2-20R07 LED 2 Line Message CentersUp to 40 Characters, MC4 Series PC Networkable LED 4 Line Message Center, MC8-16C1 LED 8 Line Lobby Message Center, MCDI Series Text Message Annunciator Driver, MCN-1-0 Message Networking Center SoftwareMultiple Sign Connectivity, MCN-2-0 Message Center SoftwareSingle Sign Connectivity, MCNET / MSS100 / MSS485 Message Center Network Adapters, Message Center Production Displays Completely customized to meet any specifications, Message Center Reception Displays Standard & customized models available, S Series DC Power Supplies Low Voltage, S1 Series Airchime Steam WhistlesIndoor or Outdoor Use |
| Related Products: |
102 Series Triliptical Stackable Status Indicator, 17500, 1884A 15 Inch Analog Clocks, 1885A 12 Inch Analog Clocks, 1886 & 1887 Series 8 Inch & 12 Inch Analog Clocks, 1888, 1889, 1899 & 2476B Series Clock Accesssories, 1893 & 1894 Series LCD Digital Clocks, 1900MS12-24 LED Wall Clock, 2000-DCT System Digital Clock Timer/Controller, 2000-SC Series System Clocks, 6000-AMFMCAS, 6000-AMFMCAS-PA, 6000-MP Series, 92-R5 Series AdaptaBeacon Light Duty Strobe, B-ER-2000 Series, Edwards Warning Siren Accessories, EG1* Series Genesis® Horns, Strobes & Horn/Strobes, EG1M Series Signal Master Synchronization ModuleMeets UL 1971 synchronization requirements, KMJ Series, MC1 Series LED 1 Line Message CentersUp to 51 Characters, MC2 Series LED 2 Line Message CentersUp to 120 Characters, MC2-20R07 LED 2 Line Message CentersUp to 40 Characters, MC4 Series PC Networkable LED 4 Line Message Center, MC8-16C1 LED 8 Line Lobby Message Center, MCDI Series Text Message Annunciator Driver |
|
|
|
|