Product Name: Electromagnetic calorimeter Model MCM10A
Product Description
OVERVIEW: -
The Yamatake model MCM10A is a custody transfer meter used to measure the calorie consumption
of air conditioning systems in buildings or shopping malls or it can be used in
district heating/cooling applications. The flow rate is measured by an electromagnetic
magnetic flow meter having field proven Yamatake technologies. It measures the flow rate of chilled water/water with glycol/hot water and calculates calorie consumption with its two temperature inputs (supply and return).
ADVANTAGES: -
Reduced total cost of ownership:
No additional computing system for calorie consumption calculation is necessary.
Precise cooling/heating cost measurement:
Yamatake electromagnetic flow meter technology ensures accurate flow measurement.
Its temperature sensor compensation function provides accurate calorie consumption measurement.
Energy efficient:
No pressure loss occurs with the electromagnetic flow meter thus resulting in less energy required
for the flow.
FEATURES: -
• The Yamatake model MCM10A has a calorie consumption calculation program.
• It has two terminals for the temperature sensor (Pt 100 RTD sensor) input (supply and return).
• The device is provided with two types of output, analog (4 to 20mA) and pulse output (totalized value).
• The Yamatake model MCM10A accumulates the totalized values of calorie consumption for
both cooling and heating modes.
Applications: -
Buildings / Shopping malls:
Calorie consumption measurement for air conditioning systems
District heating/cooling:
Calorie consumption measurement
FUNCTIONAL SPECIFICATIONS: -
Type of protection:
IEC IP65 (for indoor use)
Input signal:
Temperature (two inputs: supply and return):
3-wire Pt 100 sensor
IEC751 “Tolerance class A” is recommended.
Output signal:
Analog output:
4 to 20mA DC (flow rate)
Load resistance: 0 to 400
Pulse output:
Open collector (calorific value consumption)
Contact capacity: 30 V DC max., 100mA max.
Pulse frequency: 500 Hz max.
Pulse width: 1ms to 1s
Adjustable between 1ms and 1s or fixed at 50% of
duty.
Pulse scale: 0.01, 0.1, or 1 in the selected calorific unit.
Calorific unit:
GJ, MJ, Gcal, Mcal, MBTU, kBTU
Display: LCD
Main display: 7-segment, 8 digits for totalized calorific
value of consumption.
Sub display: 16 digits, 2 lines for mode indication, %
flow rate, calorific unit, and supply and return fluid temperatures.
Data setting:
Operation by four key switches.
Damping (for flow rate):
Adjustable between 0.5 and 199.9 seconds.
Low flow cutoff (for flow rate):
Adjustable from 0 to 10% of the setting range.
If below the selected value, th e output will be driven to the
zero flow rate signal level.
Failure diagnostics:
If the converter malfunctions, the analog output will be
automatically fixed at 3.6mA.
Power failure:
An EEPROM retains a data record of the totalized values
of the consumed calorific value for both cooling and heating
modes.
Power supply:
24 V DC ± 10%
Power consumption:
2.4 W max.
Ambient temperature limits:
0 to 50°C
Ambient humidity limits:
5 to 85% RH (no condensation)
Company Details
The success of EASE led to questions about how well robots could build structures in space. The SSL's first neutral buoyancy robot, the Beam Assembly Teleoperator (BAT), was built in 1983 specifically to construct the EASE structure. Over BAT's... more
| More Products of this Company: |
Advanced EVA Tool project, Maryland Advanced Research/Simulation suit, Ranger Neutral Buoyancy Vehicle (RNBV), Ranger Satellite Servicing System, Ranger Telerobotic Shuttle Experiment (RTSX), Supplemental Camera and Maneuvering Platform (SCAMP), Three-Dimensional Acoustic Positioning Sytems (3DAPS), Visual Positioning System |
| Related Products: |
Black Body Radiation, Digital Camera Space, Eddy Current Brakes, Eddy Current Drives, History of Space, Laptops Space, light, light, MERCURY REDSTONE VEHICLE, PDA Space, Supplemental Camera and Maneuvering Platform (SCAMP), Testing Aerospace Motors, The Cold War: At The Edge of Space, the full range, the full range, Visual Positioning System, Voyage |
| Suitable For: |
-
|
|
|
|