Product Name: MagneW 3000 PLUS Smart Electromagnetic Flowmeter Model MGG18D
Product Description
OVERVIEW: -
The MagneW 3000 PLUS ceramic lining detector is a high-performance and highly-reliable
flow meter based on Yamatake's proven MagneW 3000 flow measurement technologies.
A broader portfolio of MagneW 3000 PLUS meets various applications.
FEATURES: -
• A unique high-quality electrode structure offers the strongest ceramic lining detector against thermal
shock.
• Ceramic lining detectors range in size from 15 mm to 100 mm are available and meet various severe
applications, such as high-temperature, high-pressure, and wearing applications.
• Mirror finish surface of the ceramic lining is available for scaling applications.|
• The standard accuracy is +/- 0.5% of rate. Also available is an optional high accuracy calibration
rated at +/- 0.35% of rate (sizes of 40mm to 100mm (1-1/2 to 4 inches) , combined with MGG14C).
APPLICATIONS: -
Applicable to a wide range of applications in various industries.
Petroleum/petrochemical/chemicals
Corrosive liquids, dyes, chemicals, etc.
Public utilities
Service water, sewage, excrement, sludge, sediment slurry etc.
Steel/non-ferrous metals/ceramics
Aluminum slurry, corrosive liquids, etc.
Machinery/equipment/electric machinery
Corrosive liquids, etc.
Construction
Construction material slurry, sediment slurry,cement slurry, etc.
FUNCTIONAL SPECIFICATIONS: -
Type of protection:
JIS C 0920 waterproof model
NEMA ICS6-110 TYPE4
IEC PUBL 529 IP66
Measurable flow pressure
-0.098 to +3.92 MPa {-1 to +40 kgf/cm2}
Flange rating
JIS 10K, 20K, 30K, 40K
ANSI 150, 300, JPI 150, 300
DIN PN10, 16, 25, 40
JIS G3451 F12 (diameter 80 to 100 mm)
Ambient temperature limits
-25 to +60°C (integral model)
-30 to +80°C (integral model)
Ambient humidity limits
10 to 90% RH
Measurable electrical conductivity
Combined with model MGG14C converter 3 μS/cm or more
(in case of less than 3 μS/cm, consult your Yamatake representative)
| Related Products: |
Noise Dosimeters, Space and Airborne Systems, 1-watt DC/DCs extend reliability, 1/3 & 3/4 HP Fixed Speed, Variable Length Turbines, 10-BASE T, 100 Mhz Antenna, 100 Mhz Bistatic Ant, 108FC (Globe) / 108FCA (Angle), 108FPS PUMP SUCTION CONTROL VALVE, 190 and 191 Splicers, 1965 Bobst SP 1260E, 1973 Miehle 6 color, 50", 1988 Vega 750, 1989 Bobst Domino 90, 1995 Sakurai Oliver 272 EPII, 2 HP Fixed Speed, Variable Length Turbines, 2.5-Megapixel CMOS Industrial Camera, 200 Mhz Antenna, 2001 SBL 1300 SEF Foil Stamper, 20W power supplies are ideal drop-in replacements, 2300RG MELLTRONICS DRIVES, 25 to 600W enclosed power supplies are available as single, dual and triple output units, 2600RG MELLTRONICS DRIVES, 265A Photomultiplier Base, 270 MHz Antenna |
| Suitable For: |
-
|
|
|
|