Product Name: JTD Series of Differential Pressure Transmitters Model JTD910A/920A/930A/960A/921A/931A/961A
Product Description
OVERVIEW: -
The ST3000 ACE Smart Transmitter is a microprocessor-based smart transmitter that features
high performance and excellent stability. Capable of measuring gas, liquid, and vapor flow
rates, pressures, and liquid levels, it transmits 4 to 20 mA DC analog and digital signals according
to the measured differential pressure. It can also execute two-way communications
between the SFC (Smart Field Communicator), and, via DE protocol, with the TDCS3000 or
3000X and a database, thus facilitating self-diagnosis, range resetting, and automatic zero adjustment.
FEATURES: -
Excellent stability and high performance:
• Long-term stability has been proven in 500,000 installations worldwide.
• Unique characterization and composite semiconductor sensors realize excellent temperature
and static pressure characteristics.
Wide measuring range (rangeability):
• A wide measuring range is available from a single model. This feature is highly effective in
taking measurements over a wide range and reducing the need for reserve units. The measuring
range of the model JTD920A, for example, is 0.75 to 100 kPa (rangeability = 1 : 135).
A diverse lineup:
• A wide range of models is available to meet user requirements. They include micro-differential
pressure, standard differential pressure,high differential pressure, standard differential
pressure/high static pressure, and high differential pressure/high static pressure models.
• A wide variety of corrosion-resistant materials for wetted parts is also available.
Multiprotocol communication:
• Either analog output (4 to 20 mA DC), analog FSK output (4 to 20 mA DC) or digital output (DE protocol) is possible.
•Two-way communication using digital output facilitates self-diagnosis, range resetting, automatic zero adjustment, and other operations.
Full after-sales service program:
• A wide variety of specialized replacement kits is provided to meet customers' needs when replacing Yamatake transmitters or transmitters from other companies.
• From product delivery to replacement, we will service all your needs. Our nationwide service
network provides all the backup you require, including trial operation support and regular
maintenance.
APPLICATION: -
Petroleum / Petrochemical / Chemical:
• For strict flow control in combination with orifice plates
• For measuring pressures and liquid levels in pipes and tanks
Electric power / City gas / Other utilities:
• For measurement applications that require high degrees of stability and accuracy
Draft range applications such as semiconductor equipment manufacturing / Clean rooms:
• For applications that require highly stable, accurate measurement
Pulp and paper:
• For lines that need transmitters resistant to chemical liquids, corrosive fluids and the like.
Iron and steel / Nonferrous metal /Ceramics:
• For highly stable, accurate measurements such as furnace pressure measurement
• For lines that require stable measurement under strictly controlled (temperature, humidity, etc.)conditions
Machinery / Shipbuilding:
• For lines that require stable measurement under strictly controlled (temperature, humidity, etc.)conditions
SPECIFICATIONS: -
Output / Communication:
Analog output (4 to 20 mA DC)
Analog FSK output (4 to 20 mA DC)
(Frequency shift keying signal transmission system)
Digital output (DE protocol)
Supply voltage and load resistance:
10.8 to 45V DC. A load resistance of 250 or more
is necessary between loops.
Fill Fluid:
Silicone oil for general purpose models
Fluorine oil for oxygen and chlorine models
Ambient temperature range:
Normal operating range
-40 to 85°C for general purpose models
-15 to 65°C for general purpose model (JTD910A)
-10 to 75°C for oxygen and chlorine models
-20 to 70°C for models with digital indicators
Operative limits
-50 to 93°C for general purpose models
-40 to 70°C for general purpose model (JTD910A)
-40 to 80°C for oxygen and chlorine models
-30 to 80°C for models with digital indicators
JIS special explosion-proof models: -20 to 60°C
JIS intrinsically safe models: -10 to 60°C
Temperature ranges of wetted parts:
Normal operating range
-40 to 110°C for general purpose models
-10 to 75°C for oxygen and chlorine models
Operative limits::
-50 to 115°C for general purpose models
-40 to 80°C for oxygen and chlorine models
JIS special explosion-proof models: -20 to 110°C
JIS intrinsically safe models: -10 to 100°C
Ambient humidity range:
5 to 100% RH
Stability against supply voltage change:
± 0.005% F.S./V
Lightning protection:
Peak value of voltage surge: 100 kV
Peak value of current surge: 1000A
Dead time:
Approximately 0.4 sec.
Damping time constant:
Selectable from 0 to 32 sec. in ten stages
Waterproof / Dustproof structure:
JIS C0920 watertight: NEMA3 and 4X
JIS F8001 class 2 watertight: IEC IP67
Explosion-proof structure:
JIS special explosion-proof models: (Exd II CT4X)
JIS intrinsically safe models: (i3aG4)
| Related Products: |
"EL" SERIES OF CURRENCY CONTAINERS, "ELC" SERIES OF CURRENCY CONTAINERS, "HIGH PERFORMANCE GAS DRIVE" K-70, 'UNIQUE' TYRE TYPE COUPLINGS, 'UNIQUE' TYRE TYPE COUPLINGS, (PoE) Power over Ethernet Switches, -8322 and B-8323 Series, 034 series, 1-Part Epoxy Acrylic Concrete & Garage Floor Paint, 1-watt DC/DCs extend reliability, 1/3 & 3/4 HP Fixed Speed, Variable Length Turbines, 100 Mhz Antenna, 100 Mhz Bistatic Ant, 100SB Series PathfinderTM Heavy Duty Rotating Light, 102 Envelope Machine, 102 Series Triliptical Stackable Status Indicator, 103 & 103I Series ChameleonTM LED Multi-Status Indicator, 105 Series AdaptaBeacon Adverse Location Signal, 1064 and 1065 Series Strap Mounted Buzzer, 1066 Series High Voltage Buzzer, 108FC (Globe) / 108FCA (Angle), 108FPS PUMP SUCTION CONTROL VALVE, 1149 "EL" SERIES OF CURRENCY CONTAINERS, 1149 "EL" SERIES OF CURRENCY CONTAINERS, 115 Series Miniature LungenTM Buzzer |
|