Login:   Password:
Not Register?    Sign Up NOW!
Date: 02 December 2008
Google
 
Edge/Crossover Timing Single Channel Analyzer - Model 2037A  
Search Country   Reset filter

Edge/Crossover Timing Single Channel Analyzer - Model 2037A

Product Name: Edge/Crossover Timing Single Channel Analyzer - Model 2037A

Product Description

The CANBERRA Model 2037A analyzes the peak amplitude of energy pulses from nuclear pulse shaping amplifiers for compliance with energy levels determined by front panel controls, and generates logic outputs which are time derived by the leading edge or crossover techniques. The unit thus combines the conventional single channel analyzer function with that of an excellent but economical timing analyzer.

The leading edge timing technique finds best application in fast-shaped unipolar signals of a fairly narrow energy (pulse height) range. The crossover technique exploits the amplitude-insensitive zero voltage crossing of a bipolar pulse to provide a stable timing reference for a broad energy range. A front panel Mode switch allows selection of either timing derivation.

ENERGY

The logic output (SCA) is provided as both positive and negative NIM-level pulses for input analog pulses whose peak amplitude is between the levels determined by the Lower Level (E) and Window (ΔE) front panel ten-turn controls. Energy discrimination in the Model 2037A is sharp, precise and stable (drift is less than ±0.005%/°C, full scale). The dc coupled input allows excellent baseline stability limited only by the shaping amplifier’s restorer. These significant features permit excellent amplitude discrimination, even in high count rate spectra.

The LOWER LEVEL (E) threshold is calibrated by reference to the regulated NIM supply voltages, and is usable in a range from +0.1 to +10.0 V dc. Linearity of control is limited only by the specified ±0.25% maximum integral nonlinearity of the front panel potentiometer.

The Window (ΔE) threshold is also calibrated by reference to the regulated NIM supply voltages, and is usable in a range from the Lower Level (E) setting to +10.0 V dc. A front panel ΔE Range switch allows use of a 1.0 V full scale range for very fine adjustments of the desired energy window.

TIMING

For the leading edge mode, a true low level leading edge technique is employed to minimize timing jitter. To simplify setup and adjustment, the threshold level for the leading edge timing discriminator is set to track the Lower Level (E) control at 50%, up to a limit of 200 mV dc. For reasonably large input pulse heights, then, timing is referenced to the 200 mV dc level. To simplify adjustment of timing dwell for the rise time of the input pulse, that function has been incorporated in an extended range DELAY control. The user can simply set the selected delay for the known time-to-peak of the input pulse (or at least 2X the shaping time constant used in a near-Gaussian pulse) without the need for tedious oscilloscope trimming.

Features 
Leading edge or crossover-type timing derivation
Dynamic range 100:1
Pileup rejection logic
Exceptional stability – dc-coupled input
Positive and negative timing SCA outputs
Source matched logic outputs
Variable delay of up to 11 ìs

Company Details

For over 35 years, the name Canberra has been known for world class nuclear measurement equipment and services. Now... meet the new Canberra.

... more

More Products of this Company: ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, ADM606M Multi-purpose Radiation Monitor, AFT Research Amplifier - Model 2025, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, Alpha Spectrometers and Accessories, AMP/TSCA - Model 2015A, Arrangement of 2 or more Germanium Detectors, BARA 31 Gamma Alarm Beacon, Bin/Power Supply - Model 2000/2100, CAM110FF Series Continuous Air Monitors, Charge Amplifiers for Bonner Multisphere Systems, Charge Amplifiers for Neutron Scattering, Digital Signal Processor - Model 2060, Eclipse - Control and Analysis Software for S5XLB and LB5500 Systems, Front Opening Split-Top Shield - Model 767, G64 Gamma Monitor, Gamma Analyst Integrated Gamma Spectromete, Ge Clover Detectors, Ge Encapsulated Detectors, Ge Segmented Coaxial Detectors, Geiger Mueller Detectors - GP Series, Geiger-Mueller (GM) Tubes, iCAM Alpha/Beta Air Monito, ICB Programmable Digital Signal Processor - Model 9660, iMatic Gas-less Automatic Alpha/Beta Counting System, iSolo Gas-less Manual Alpha / Beta Counting System, LB4100 Multi-Detector Low Background Alpha/Beta Counting System, LB5500 Large Area Automatic Low Background Alpha/Beta Counting System, Linear Ratemeter - Model 2081, Model 512 - Dual Counter/Timer, Model 8224 Analog Multiplexer, Model 8715 - Analog-to-Digital Converte, Model 9635 - ICB Programmable ADC, Model Calibrator/M Semi-Automatic Calibration and Check Bench, Networked Continuous Air Monitor (NetCam), Neutron Detectors - NP Series, PGM102 Portable Gas Monitor, Photomultiplier Tube Base/Preamplifier - Model 2007/2007P, Scintillation Detectors - Model 802, Series 5 APC Console Based Automatic Alpha/Beta/Gamma Counting Systems, Series 5E Console-Based Automatic Low Background Alpha/Beta Counting System, Series 5XLB Automatic Low Background Alpha/Beta Counting System, Si(Li) Charged Particle Detectors with Transmission Mounts, Si(Li) Segmented X-ray Detectors, Silicon (Li) Detector Systems, Spectroscopy Amplifier - Model 2026, Standard PIPS Detectors, TAM Series Tritium Air Monitor, X-PIPS Detector
Related Products: 265A Photomultiplier Base, 296 ScintiPack Photomultiplier Base with Preamp and HV Supply, 414A Fast Coincidence, 427A Delay Amplifier, 439 Digital Current Integrator, 460 Delay Line Amplifier, 474 Timing Amplifier, 533 DUAL SUM AND INVERT AMPLIFIER, 542 Linear Gate and Stretcher, 570 AMPLIFIER, 572A AMPLIFIER, 590A AMPLIFIER AND TIMING SINGLE CHANNEL ANALYZER, 671 SPECTROSCOPY AMPLIFIER, 673 Spectroscopy Amplifier and Gated Integrato, 863 QUAD TIMING FILTER AMPLIFIER, 9302 AMPLIFIER DISCRIMINATOR, 9327 1-GHz Amplifier and Timing Discriminator, ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, ADM606M Multi-purpose Radiation Monitor, AFT Research Amplifier - Model 2025, Alpha Analyst Integrated Alpha Spectrometer, Alpha Sentry CAM, Alpha Spectrometers and Accessories, AMP/TSCA - Model 2015A, Arrangement of 2 or more Germanium Detectors
Home | Members.Benefit | Privacy.Policy | Bookmark.This.Page | Contact.Us
© 2006 - 2007 4engr. All Rights reserved |Recommended Engineering Sites:| Center for Respect of Life and Environment | Internet Dictionary|Enginering intent(Engineering Events) | Map Archive