Product Name: Model 8715 - Analog-to-Digital Converte
Product Description
The Model 8715 Analog-to-Digital Converter (ADC) is an ultra- fast 900 ns, Fixed Dead Time, analog-to-digital-converter for high count rate nuclear spectroscopy. This highly linear, 8K ADC contributes no system dead time to spectroscopy systems using traditional Gaussian or Triangular Shaping amplifiers.
The Model 8715 boasts differential and integral linearity performance that until now was only possible with Wilkinson ADCs. Its exceptional linearity improves peak shape and resolution, thereby improving the overall performance of your spectroscopy system. It requires a single NIM width.
Concentric Gain and Range controls together with Digital Offset allow the user to maximize the use of limited MCA memory by selecting only the specific energy range of interest. This can be particularly useful for multi-input applications such as alpha spectroscopy, thus eliminating the need for older biased amplifiers. These digital controls accomplish the same end, more accurately and repeatably.
Conversion for the Pulse Height Analysis (PHA) mode can be initiated AUTOmatically using an internal peak detector operating on the input pulse, or can be DELAYED up to 100 ìs after the leading edge of the input pulse passes the input threshold. A front panel INSPEct test point is provided so that the user can monitor the Linear Gate (LG) time between LLD crossing and the beginning of conversion for either mode. Conversions may be enabled/disabled by COINCidence/ANTIcoincidence gating applied at any time during the Linear Gate interval.
Voltage sampling and subsequent conversion for the Sampled Voltage Analysis (SVA) mode is initiated by the leading and trailing edges, respectively, of a Gate pulse applied in the Coincidence mode. The same Lower and Upper Level Discriminators (LLD/ULD) limits are used for acceptance of the peak input during the positive gate time. The Model 8715 provides front panel, screwdriver adjustable, multi-turn potentiometers for the control of the LLD/ ULD, as well as the ADC Zero.
The Model 8715 provides the connections required for use with current CANBERR A amplifiers that perform pileup rejection and live time correction (PUR/LTC). These ADC/amplifier interfaces are also required to use the Westphal Loss Free Counting or Precision Live Time techniques.2
The Model 8715 ADC is fully compatible with all current CANBERRA MCAs (with external ADC interface options such as the Model 556A), Digital Stabilizer and Analog Multiplexers.
Features
900 ns Fixed Dead Time ADC
8K channel resolution
Digital offset in 128 channel increments
Exceptional linearity (differential <±0.9%, integral <±0.025%)
Pulse Height Analysis using either automatic peak detection or delayed triggering
Analog Sample Voltage Analysis
Pulse pileup rejection and live time correction interfaces
Compatible with Loss Free Counting Systems1
Company Details
For over 35 years, the name Canberra has been known for world
class nuclear measurement equipment and
services. Now... meet the new
Canberra.
... more
| More Products of this Company: |
ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, ADM606M Multi-purpose Radiation Monitor, AFT Research Amplifier - Model 2025, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, Alpha Spectrometers and Accessories, AMP/TSCA - Model 2015A, Arrangement of 2 or more Germanium Detectors, BARA 31 Gamma Alarm Beacon, Bin/Power Supply - Model 2000/2100, CAM110FF Series Continuous Air Monitors, Charge Amplifiers for Bonner Multisphere Systems, Charge Amplifiers for Neutron Scattering, Digital Signal Processor - Model 2060, Eclipse - Control and Analysis Software for S5XLB and LB5500 Systems, Edge/Crossover Timing Single Channel Analyzer - Model 2037A, Front Opening Split-Top Shield - Model 767, G64 Gamma Monitor, Gamma Analyst Integrated Gamma Spectromete, Ge Clover Detectors, Ge Encapsulated Detectors, Ge Segmented Coaxial Detectors, Geiger Mueller Detectors - GP Series, Geiger-Mueller (GM) Tubes, iCAM Alpha/Beta Air Monito, ICB Programmable Digital Signal Processor - Model 9660, iMatic Gas-less Automatic Alpha/Beta Counting System, iSolo Gas-less Manual Alpha / Beta Counting System, LB4100 Multi-Detector Low Background Alpha/Beta Counting System, LB5500 Large Area Automatic Low Background Alpha/Beta Counting System, Linear Ratemeter - Model 2081, Model 512 - Dual Counter/Timer, Model 8224 Analog Multiplexer, Model 9635 - ICB Programmable ADC, Model Calibrator/M Semi-Automatic Calibration and Check Bench, Networked Continuous Air Monitor (NetCam), Neutron Detectors - NP Series, PGM102 Portable Gas Monitor, Photomultiplier Tube Base/Preamplifier - Model 2007/2007P, Scintillation Detectors - Model 802, Series 5 APC Console Based Automatic Alpha/Beta/Gamma Counting Systems, Series 5E Console-Based Automatic Low Background Alpha/Beta Counting System, Series 5XLB Automatic Low Background Alpha/Beta Counting System, Si(Li) Charged Particle Detectors with Transmission Mounts, Si(Li) Segmented X-ray Detectors, Silicon (Li) Detector Systems, Spectroscopy Amplifier - Model 2026, Standard PIPS Detectors, TAM Series Tritium Air Monitor, X-PIPS Detector |
| Related Products: |
265A Photomultiplier Base, 296 ScintiPack Photomultiplier Base with Preamp and HV Supply, 414A Fast Coincidence, 427A Delay Amplifier, 439 Digital Current Integrator, 460 Delay Line Amplifier, 474 Timing Amplifier, 533 DUAL SUM AND INVERT AMPLIFIER, 542 Linear Gate and Stretcher, 570 AMPLIFIER, 572A AMPLIFIER, 590A AMPLIFIER AND TIMING SINGLE CHANNEL ANALYZER, 671 SPECTROSCOPY AMPLIFIER, 673 Spectroscopy Amplifier and Gated Integrato, 863 QUAD TIMING FILTER AMPLIFIER, 9302 AMPLIFIER DISCRIMINATOR, 9327 1-GHz Amplifier and Timing Discriminator, ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, ADM606M Multi-purpose Radiation Monitor, AFT Research Amplifier - Model 2025, Alpha Analyst Integrated Alpha Spectrometer, Alpha Sentry CAM, Alpha Spectrometers and Accessories, AMP/TSCA - Model 2015A, Bin/Power Supply - Model 2000/2100 |
|
|
|
|