Spectroscopy Amplifier - Model 2026  
Search Country   Reset filter

Spectroscopy Amplifier - Model 2026

Product Name: Spectroscopy Amplifier - Model 2026

Product Description

The Model 2026 amplifier provides the features and performance of a research amplifier in an easy to use single width NIM module. Now you can have the flexibility you need without the amplifier set-up and adjustment aggravation you don’t need.

The Model 2026 lets you select either Gaussian or Triangular pulse shaping for the Unipolar output with a convenient front panel switch. In addition, it offers a choice of six front panel switch-selectable shaping time constants for each of the pulse shaping methods. This direct control of both the shaping method
and time constants lets you select the configuration that will optimize resolution and throughput performance based on your application.

The 2026’s Pileup Rejector/Live Time Corrector (PUR/LTC) circuitry allows quantitative gamma analysis with minimal dependence on system count rate. The PUR circuit interrogates incoming pulses for pile up and generates a signal that prevents the ADC from converting the piled up events. The LTC circuit then generates a system dead time that extends the collection time to compensate for the events lost due to pileup rejection. The result: lower background, better resolution and accurate live time information for the best possible analysis results.

But don’t worry about setting up this amplifier. Many of the 2026’s features are self-adjusting so you get the performance you need and a trouble-free setup. The 2026 automatically adjusts the PUR threshold just above your system
noise level, insuring PUR efficiency and minimizing the spectral distortion caused by pile up at high count rates. The restoration rate and threshold of the gated baseline restorer are also automatically optimized for both low and high count rate applications. With all these automatic features the 2026 gives you consistently better data for your activity calculations, regardless of the count rate, the application or the operator.

The 2026 lets you position peaks precisely and easily with its Super Fine Gain (SFG) control. The SFG provides gain resolution better than 1 in 16 000 (0.00625%), allowing greater precision for more accurate peak location in less time. This feature is now a requirement, instead of a luxury, for most spectroscopy
systems. This is especially true in applications using detector arrays in which the inputs from several detectors must be combined into a single spectrum.

The excellent overload recovery characteristics of the 2026 make it ideal for use with today’s high throughput reset preamplifiers such as the CANBERRA 2101 Transistor Reset Preamplifier. This allows you to assemble a high resolution spectroscopy system without the energy rate limitations normally associated with RC preamplifiers. 

The Model 2026’s wide gain range allows you to use it with a wide range of detectors including germanium, silicon, scintillation, proportional counters or pulsed ion chambers. The versatility of the 2026 is further enhanced by a bipolar output for use in timing and gating applications.

Features
Gaussian/Triangular shaping 
Super fine gain control 
Pileup rejector and live time corrector 
Automatic baseline recovery rate and threshold 
Differential input 
Excellent overload recovery 
Compact single width NIM

Company Details

For over 35 years, the name Canberra has been known for world class nuclear measurement equipment and services. Now... meet the new Canberra.

... more

More Products of this Company: ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, ADM606M Multi-purpose Radiation Monitor, AFT Research Amplifier - Model 2025, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, Alpha Spectrometers and Accessories, AMP/TSCA - Model 2015A, Arrangement of 2 or more Germanium Detectors, BARA 31 Gamma Alarm Beacon, Bin/Power Supply - Model 2000/2100, CAM110FF Series Continuous Air Monitors, Charge Amplifiers for Bonner Multisphere Systems, Charge Amplifiers for Neutron Scattering, Digital Signal Processor - Model 2060, Eclipse - Control and Analysis Software for S5XLB and LB5500 Systems, Edge/Crossover Timing Single Channel Analyzer - Model 2037A, Front Opening Split-Top Shield - Model 767, G64 Gamma Monitor, Gamma Analyst Integrated Gamma Spectromete, Ge Clover Detectors, Ge Encapsulated Detectors, Ge Segmented Coaxial Detectors, Geiger Mueller Detectors - GP Series, Geiger-Mueller (GM) Tubes, iCAM Alpha/Beta Air Monito, ICB Programmable Digital Signal Processor - Model 9660, iMatic Gas-less Automatic Alpha/Beta Counting System, iSolo Gas-less Manual Alpha / Beta Counting System, LB4100 Multi-Detector Low Background Alpha/Beta Counting System, LB5500 Large Area Automatic Low Background Alpha/Beta Counting System, Linear Ratemeter - Model 2081, Model 512 - Dual Counter/Timer, Model 8224 Analog Multiplexer, Model 8715 - Analog-to-Digital Converte, Model 9635 - ICB Programmable ADC, Model Calibrator/M Semi-Automatic Calibration and Check Bench, Networked Continuous Air Monitor (NetCam), Neutron Detectors - NP Series, PGM102 Portable Gas Monitor, Photomultiplier Tube Base/Preamplifier - Model 2007/2007P, Scintillation Detectors - Model 802, Series 5 APC Console Based Automatic Alpha/Beta/Gamma Counting Systems, Series 5E Console-Based Automatic Low Background Alpha/Beta Counting System, Series 5XLB Automatic Low Background Alpha/Beta Counting System, Si(Li) Charged Particle Detectors with Transmission Mounts, Si(Li) Segmented X-ray Detectors, Silicon (Li) Detector Systems, Standard PIPS Detectors, TAM Series Tritium Air Monitor, X-PIPS Detector
Related Products: 265A Photomultiplier Base, 296 ScintiPack Photomultiplier Base with Preamp and HV Supply, 414A Fast Coincidence, 427A Delay Amplifier, 439 Digital Current Integrator, 460 Delay Line Amplifier, 474 Timing Amplifier, 533 DUAL SUM AND INVERT AMPLIFIER, 542 Linear Gate and Stretcher, 570 AMPLIFIER, 572A AMPLIFIER, 590A AMPLIFIER AND TIMING SINGLE CHANNEL ANALYZER, 671 SPECTROSCOPY AMPLIFIER, 673 Spectroscopy Amplifier and Gated Integrato, 863 QUAD TIMING FILTER AMPLIFIER, 9302 AMPLIFIER DISCRIMINATOR, 9327 1-GHz Amplifier and Timing Discriminator, ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, ADM606M Multi-purpose Radiation Monitor, AFT Research Amplifier - Model 2025, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, Alpha Spectrometers and Accessories, AMP/TSCA - Model 2015A