Login:   Password:
Not Register?    Sign Up NOW!
Date: 02 December 2008
Google
 
TAM Series Tritium Air Monitor  
Search Country   Reset filter

TAM Series Tritium Air Monitor

Product Name: TAM Series Tritium Air Monitor

Product Description

Canberra’s tritium monitors consist of two basic units, one of which is portable and one that is used for fixed applications. Both of these are able to accommodate serial communications with a remote processing and display unit. These units have the capacity to draw air from the atmosphere, pass it through a filter to remove the dust, and measure the tritium concentration in DAC units on a digital/analog display. Measurement ranges vary slightly and all Models have interference immunity from other airborne radioactive gasses and vapors such as Argon, Xenon, Iodine, etc. 
2.4 liters Flow-though dual sealed ion chamber
Removable filter for particulate contamination
Ion trap
Gamma compensation
Automatic Radon substraction
Solid state electrometer
Front panel electrometer output (0-5 V DC)
Weight: 25 lbs (11.4 kg)
For glove boxes, NPPs Neutron generators, Cyclotron and Accelerators

Model:
Applications :
Power:
Range :
Volume :
Advantages :
TAM-100D
Fixed
AC only
0.5 to 106 µCi/m3
7-9 l/mn
Heater for fast cleaning
Quicker decontamination
More Rigorous test/calibration
TAM-73D
Portable
AC & Batteries
1 to 106 µCi/m3
3-5 l/mn
Rechargable Battery
backup for 2 hours

Company Details

For over 35 years, the name Canberra has been known for world class nuclear measurement equipment and services. Now... meet the new Canberra.

... more

More Products of this Company: ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, ADM606M Multi-purpose Radiation Monitor, AFT Research Amplifier - Model 2025, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, Alpha Spectrometers and Accessories, AMP/TSCA - Model 2015A, Arrangement of 2 or more Germanium Detectors, BARA 31 Gamma Alarm Beacon, Bin/Power Supply - Model 2000/2100, CAM110FF Series Continuous Air Monitors, Charge Amplifiers for Bonner Multisphere Systems, Charge Amplifiers for Neutron Scattering, Digital Signal Processor - Model 2060, Eclipse - Control and Analysis Software for S5XLB and LB5500 Systems, Edge/Crossover Timing Single Channel Analyzer - Model 2037A, Front Opening Split-Top Shield - Model 767, G64 Gamma Monitor, Gamma Analyst Integrated Gamma Spectromete, Ge Clover Detectors, Ge Encapsulated Detectors, Ge Segmented Coaxial Detectors, Geiger Mueller Detectors - GP Series, Geiger-Mueller (GM) Tubes, iCAM Alpha/Beta Air Monito, ICB Programmable Digital Signal Processor - Model 9660, iMatic Gas-less Automatic Alpha/Beta Counting System, iSolo Gas-less Manual Alpha / Beta Counting System, LB4100 Multi-Detector Low Background Alpha/Beta Counting System, LB5500 Large Area Automatic Low Background Alpha/Beta Counting System, Linear Ratemeter - Model 2081, Model 512 - Dual Counter/Timer, Model 8224 Analog Multiplexer, Model 8715 - Analog-to-Digital Converte, Model 9635 - ICB Programmable ADC, Model Calibrator/M Semi-Automatic Calibration and Check Bench, Networked Continuous Air Monitor (NetCam), Neutron Detectors - NP Series, PGM102 Portable Gas Monitor, Photomultiplier Tube Base/Preamplifier - Model 2007/2007P, Scintillation Detectors - Model 802, Series 5 APC Console Based Automatic Alpha/Beta/Gamma Counting Systems, Series 5E Console-Based Automatic Low Background Alpha/Beta Counting System, Series 5XLB Automatic Low Background Alpha/Beta Counting System, Si(Li) Charged Particle Detectors with Transmission Mounts, Si(Li) Segmented X-ray Detectors, Silicon (Li) Detector Systems, Spectroscopy Amplifier - Model 2026, Standard PIPS Detectors, X-PIPS Detector
Related Products: 533 DUAL SUM AND INVERT AMPLIFIER, 671 SPECTROSCOPY AMPLIFIER, 9302 AMPLIFIER DISCRIMINATOR, ADM606M Multi-purpose Radiation Monitor, ALPHA (NORM) CONTAMINATION IN PIPES, TOOLS AND OBJECTS, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, ALPHA SURFACE CONTAMINATION, BARA 31 Gamma Alarm Beacon, Bin/Power Supply - Model 2000/2100, CAM110FF Series Continuous Air Monitors, Custome Electret material made from FEP Teflon, Eclipse - Control and Analysis Software for S5XLB and LB5500 Systems, ENVIRONMENTAL AND WORK PLACE GAMMA RADIATION, G64 Gamma Monitor, Gamma Analyst Integrated Gamma Spectromete, Geiger Mueller Detectors - GP Series, Geiger-Mueller (GM) Tubes, HM413 CAMAC FERAbus Histogramming Memory, iCAM Alpha/Beta Air Monito, iSolo Gas-less Manual Alpha / Beta Counting System, LB4100 Multi-Detector Low Background Alpha/Beta Counting System, LB5500 Large Area Automatic Low Background Alpha/Beta Counting System, LOW ENERGY XRAYS mammography air scatter skyshine video terminal
Home | Members.Benefit | Privacy.Policy | Bookmark.This.Page | Contact.Us
© 2006 - 2007 4engr. All Rights reserved |Recommended Engineering Sites:| Center for Respect of Life and Environment | Internet Dictionary|Enginering intent(Engineering Events) | Map Archive