Product Name: PGM102 Portable Gas Monitor

Product Description

The PGM102 is a self-contained mobile monitoring/sample collection station for radioactive noble gases, particulates, iodines and tritium in a gaseous sample media. The inlet gas sample passes first through a dual charcoal cartridge and a 0.3 micron filter paper which removes iodines and particulates from the sample. It then passes through an unshielded 8.3 L counting chamber with a dual phosphor scintillation detector (plastic scintillator and BGO crystal). The BGO crystal provides a gamma activity signal with a slower rise time pulse, thus allowing it to be identified by the preamplifier and used as a compensating signal for the gamma background.

CANBERRA’s full featured ADM606M Control and Display Unit processes the detector (logic) signals from the preamplifier and data from other sensors to provide live time digital display and alarm functions. It also functions as the control unit and display for the sample collection systems.

The PGM102 gas monitoring station provides independent sampling systems to collect quantitative samples for laboratory analysis for tritium, iodine, particulate, and noble gas activity. Air sample flow rates are controlled and measured by mass flow rate controllers for both the monitoring and sample collection channels to allow calculation of activity concentration in the gaseous media.

Functionally, the PGM102 comprises several standard CANBERRA instrument modules interconnected into a stand-alone system on a rugged handcart frame. Each monitoring and sampling subsystem includes the required isolation valves, flow indicators, quick connect fittings, and connecting hoses to provide jobsite convenience without sacrificing the laboratory level sensitivity and accuracy of the initial instruments. Workers in protective clothing can readily move the handcart station to a selected site, connect the electrical and pneumatic systems, and activate the monitoring station functions in a fraction of the time required to set up separate monitoring and sampling systems.

The PGM102 is designed for use at locations where ac electrical power and a source of pressure or vacuum is present for transport of the sample through the monitoring system. An external vacuum pumping system may be connected to the air outlet connection if the inlet sample flow is not pressurized.

Features
Portable handcart station for convenient radiation monitoring/sampling of gases at the work site
Sample collector systems for particulates, iodine, tritium, and noble gases
Sensitive noble gas and tritium monitoring with 8.3 L counting chamber
Bubbler-type tritium collectors
Two mass flow rate-controllers; one for particulate/iodine totalization and one for tritium totalization
Automatic gamma background subtraction
Drift-free gain stabilization circuitry
Flexible multi-functional electronics module for display, control, and communications
Quick-connect fittings, isolation valves, and control valves to set flow rates
Mating armored hoses included

Major Assemblies
ADM606M multi-function control and display unit
MD455E beta/gamma extended range detector
ILF-200 fixed filter cartridge P/I collector
TBC100 tritium bubbler collector system
PA-300E preamplifier
MG-1U gas sampler

Company Details

For over 35 years, the name Canberra has been known for world class nuclear measurement equipment and services. Now... meet the new Canberra.

... more

More Products of this Company: ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, ADM606M Multi-purpose Radiation Monitor, AFT Research Amplifier - Model 2025, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, Alpha Spectrometers and Accessories, AMP/TSCA - Model 2015A, Arrangement of 2 or more Germanium Detectors, BARA 31 Gamma Alarm Beacon, Bin/Power Supply - Model 2000/2100, CAM110FF Series Continuous Air Monitors, Charge Amplifiers for Bonner Multisphere Systems, Charge Amplifiers for Neutron Scattering, Digital Signal Processor - Model 2060, Eclipse - Control and Analysis Software for S5XLB and LB5500 Systems, Edge/Crossover Timing Single Channel Analyzer - Model 2037A, Front Opening Split-Top Shield - Model 767, G64 Gamma Monitor, Gamma Analyst Integrated Gamma Spectromete, Ge Clover Detectors, Ge Encapsulated Detectors, Ge Segmented Coaxial Detectors, Geiger Mueller Detectors - GP Series, Geiger-Mueller (GM) Tubes, iCAM Alpha/Beta Air Monito, ICB Programmable Digital Signal Processor - Model 9660, iMatic Gas-less Automatic Alpha/Beta Counting System, iSolo Gas-less Manual Alpha / Beta Counting System, LB4100 Multi-Detector Low Background Alpha/Beta Counting System, LB5500 Large Area Automatic Low Background Alpha/Beta Counting System, Linear Ratemeter - Model 2081, Model 512 - Dual Counter/Timer, Model 8224 Analog Multiplexer, Model 8715 - Analog-to-Digital Converte, Model 9635 - ICB Programmable ADC, Model Calibrator/M Semi-Automatic Calibration and Check Bench, Networked Continuous Air Monitor (NetCam), Neutron Detectors - NP Series, Photomultiplier Tube Base/Preamplifier - Model 2007/2007P, Scintillation Detectors - Model 802, Series 5 APC Console Based Automatic Alpha/Beta/Gamma Counting Systems, Series 5E Console-Based Automatic Low Background Alpha/Beta Counting System, Series 5XLB Automatic Low Background Alpha/Beta Counting System, Si(Li) Charged Particle Detectors with Transmission Mounts, Si(Li) Segmented X-ray Detectors, Silicon (Li) Detector Systems, Spectroscopy Amplifier - Model 2026, Standard PIPS Detectors, TAM Series Tritium Air Monitor, X-PIPS Detector
Related Products: 265A Photomultiplier Base, 296 ScintiPack Photomultiplier Base with Preamp and HV Supply, 414A Fast Coincidence, 427A Delay Amplifier, 439 Digital Current Integrator, 460 Delay Line Amplifier, 474 Timing Amplifier, 533 DUAL SUM AND INVERT AMPLIFIER, 542 Linear Gate and Stretcher, 570 AMPLIFIER, 572A AMPLIFIER, 590A AMPLIFIER AND TIMING SINGLE CHANNEL ANALYZER, 671 SPECTROSCOPY AMPLIFIER, 673 Spectroscopy Amplifier and Gated Integrato, 863 QUAD TIMING FILTER AMPLIFIER, 9302 AMPLIFIER DISCRIMINATOR, 9327 1-GHz Amplifier and Timing Discriminator, ADM606M Multi-purpose Radiation Monitor, ALPHA (NORM) CONTAMINATION IN PIPES, TOOLS AND OBJECTS, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, ALPHA SURFACE CONTAMINATION, BARA 31 Gamma Alarm Beacon, Bin/Power Supply - Model 2000/2100
Home | Members.Benefit | Privacy.Policy | Bookmark.This.Page | Contact.Us
© 2006 - 2007 4engr. All Rights reserved |Recommended Engineering Sites:| Center for Respect of Life and Environment | Internet Dictionary|Enginering intent(Engineering Events) | Map Archive