Product Name: ADM606M Multi-purpose Radiation Monitor
Product Description
Supports up to three SMART probe detectors
Portable or wall-mountable
Six-button keypad for control of mode, display and alarm functions
Vacuum fluorescent display, 2 x 20 character alphanumeric and bargraph
Dose and dose rate alarms (visual and audible)
Internal self-diagnostics with display and alarm
110/220 V ac, 50/60 Hz or battery operation
Built-in lithium battery back-up for clock and data
Multiple analog and digital I/O ports
Key switch to prevent unauthorized use or changes to settings
CMOS low power technology ¨C 16 W total
Stand-alone operation or computer-based system use
Description
Model ADM606M ten decade radiation monitor is both a rate-meter and a scaler. The ADM606M supports the CANBERRA family of
SMART probes for monitoring all types of radiation including alpha, beta, gamma, x-ray, and neutron.
CANBERRA's Model ADM606M is microprocessor-based with an auto-ranging digital/analog display that provides both high accuracy and trending of results. This multi-detector capability allows it to be configured as an area, process or effluent monitoring system. Using
SMART probes allows the ADM606M to automatically interrogate the probe and determine probe type and the relative operation and calibration constants. The readout display units are automatically adjusted to correspond to the probe type. The ADM606M is capable of utilizing simultaneous inputs from up to three separate
SMART detectors.
Displays
The ADM606M has a bright, sharp vacuum fluorescent display which permits easy viewing of the radiation reading, both from a distance and at an acute angle. The use of a floating decimal point and auto-ranging units of measurement reduce the possibility of operator error when determining the amount of radiation. The type of radiation being measured is a function of the detector type (e.g., beta, gamma, neutron, etc.) and is displayed in conjunction with the radiation measurement. The display features a
scrolling two detector display of any two user-selectable detector inputs at one time and will default to probe one during normal use. When used to display two channels, the information is digitally displayed. When a single channel is displayed, both a digital and analog bargraph are used. This allows all pertinent measurement information to be displayed as desired. Both visual and audible alarms occur when radiation levels exceed userselectable set-points. Other user-selectable modes provide display and control functions such as accumulated dose, dose rate and scaler function. Units may be displayed in either R/hr, Ci/cc or si units (e.g., Sv/hr, Bq/l).
Controls
The ADM606M has two basic controls; a key-lock switch and a keypad. The key-lock switch provides the primary OFF/KEYPAD/ON control of the rate-meter, and incorporates a
lock out position to eliminate tampering by unauthorized personnel. When the key-lock switch is in the KEYPAD position, the key cannot be removed and operational parameters may be modified. When the key is in the ON position, the key may be removed and the operational parameters can only be interrogated but not modified.
Input/Output Interface
The input/output interface offers the user various methods to interface the ADM606M with ancillary or peripheral equipment. These various methods include relay contacts, analog outputs, and serial communications. Each High, Alert, and Fail alarm has a separate SPDT relay for interfacing to external devices. The ADM606M may be configured to operate in either of two alarm modes; alarm relay normally energized (fail-safe mode) and alarm relay not energized on alarm (non-fail-safe mode). The ADM606M has three standard analog outputs which may be configured in any combination of 0-10 V dc and 4-20 mA dc. The analog outputs may be scaled either lin-log (linear between log decades) or log-log (log between log decades). The serial communications port may be used to change the algorithm from a log-lin analog output to a log-log analog output. Two serial ports are available for remote communications. These serial ports allow the ADM606M to be linked to a host computer and other ancillary and peripheral instrumentation over a bi-directional local area network. Standard communications protocol available at the serial ports is RS-485 and RS-232C. The RS-485 protocol is used for networking and moderate distance communications. The RS-232C protocol is used for limited distance communications with a recorder or a printer. It may also be used with a portable computer to do system debug diagnostics or to change stored operational data.
Historical Data
Historical data is stored within the memory of the ADM606M. Historical data consists of stored data points for radiation, alarms, and loss of power. Stored data includes 30 data points each of one minute, ten minute, one hour, and one-day readings. Historical data is stored in a non-volatile 16 k-Byte memory, and is backed up by a lithium battery. Each historical data point contains the measurement data and time, the data collection period, and the accumulated dose and counts. Historical data stored within the ADM606M may be downloaded to a computer for report generation or analysis.
Software Interface
Two software programs are available to interface an ADM606M with a computer. One is a simple program (ADMCOM) used to provide a remote readout capability for the ADM606M and control over functions such as alarm set point adjustment, historical data collection, and timekeeping. The other, RADACS, is a comprehensive Radiological Assessment Display and Control Software program used for connecting multiple serial communication devices to a single computer. RADACS creates a complete monitoring network with custom graphical displays depicting facility layouts and complete
Real-Time tracking and trending functions.
Company Details
For over 35 years, the name Canberra has been known for world
class nuclear measurement equipment and
services. Now... meet the new
Canberra.
... more
| More Products of this Company: |
ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, AFT Research Amplifier - Model 2025, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, Alpha Spectrometers and Accessories, AMP/TSCA - Model 2015A, Arrangement of 2 or more Germanium Detectors, BARA 31 Gamma Alarm Beacon, Bin/Power Supply - Model 2000/2100, CAM110FF Series Continuous Air Monitors, Charge Amplifiers for Bonner Multisphere Systems, Charge Amplifiers for Neutron Scattering, Digital Signal Processor - Model 2060, Eclipse - Control and Analysis Software for S5XLB and LB5500 Systems, Edge/Crossover Timing Single Channel Analyzer - Model 2037A, Front Opening Split-Top Shield - Model 767, G64 Gamma Monitor, Gamma Analyst Integrated Gamma Spectromete, Ge Clover Detectors, Ge Encapsulated Detectors, Ge Segmented Coaxial Detectors, Geiger Mueller Detectors - GP Series, Geiger-Mueller (GM) Tubes, iCAM Alpha/Beta Air Monito, ICB Programmable Digital Signal Processor - Model 9660, iMatic Gas-less Automatic Alpha/Beta Counting System, iSolo Gas-less Manual Alpha / Beta Counting System, LB4100 Multi-Detector Low Background Alpha/Beta Counting System, LB5500 Large Area Automatic Low Background Alpha/Beta Counting System, Linear Ratemeter - Model 2081, Model 512 - Dual Counter/Timer, Model 8224 Analog Multiplexer, Model 8715 - Analog-to-Digital Converte, Model 9635 - ICB Programmable ADC, Model Calibrator/M Semi-Automatic Calibration and Check Bench, Networked Continuous Air Monitor (NetCam), Neutron Detectors - NP Series, PGM102 Portable Gas Monitor, Photomultiplier Tube Base/Preamplifier - Model 2007/2007P, Scintillation Detectors - Model 802, Series 5 APC Console Based Automatic Alpha/Beta/Gamma Counting Systems, Series 5E Console-Based Automatic Low Background Alpha/Beta Counting System, Series 5XLB Automatic Low Background Alpha/Beta Counting System, Si(Li) Charged Particle Detectors with Transmission Mounts, Si(Li) Segmented X-ray Detectors, Silicon (Li) Detector Systems, Spectroscopy Amplifier - Model 2026, Standard PIPS Detectors, TAM Series Tritium Air Monitor, X-PIPS Detector |
| Related Products: |
427A Delay Amplifier, 533 DUAL SUM AND INVERT AMPLIFIER, 570 AMPLIFIER, 572A AMPLIFIER, 590A AMPLIFIER AND TIMING SINGLE CHANNEL ANALYZER, 671 SPECTROSCOPY AMPLIFIER, 673 Spectroscopy Amplifier and Gated Integrato, 863 QUAD TIMING FILTER AMPLIFIER, 9302 AMPLIFIER DISCRIMINATOR, ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, AFT Research Amplifier - Model 2025, ALPHA (NORM) CONTAMINATION IN PIPES, TOOLS AND OBJECTS, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, Alpha Spectrometers and Accessories, ALPHA SURFACE CONTAMINATION, AMP/TSCA - Model 2015A, Arrangement of 2 or more Germanium Detectors, BARA 31 Gamma Alarm Beacon, Bin/Power Supply - Model 2000/2100, CAM110FF Series Continuous Air Monitors, Charge Amplifiers for Bonner Multisphere Systems, Charge Amplifiers for Neutron Scattering, Chemical Weapons Assay |
|