Product Name: Ge Clover Detectors
Product Description
Features
High photopeak efficiency in ‘add-back’ mode
Good energy resolution
Good timing response
Reduced vulnerability to neutron damages
Reduction of Doppler broadening even more improved when using segmented crystals
Good sensivity to gamma ray polarization.
Description
In the CLOVER detector assembly, the crystals are hold only by the rear side thus reducing the quantity of material surrounding the crystal and improving peak to background ratio. Moreover, crystals are packed very closely together to improve the add-back factor (Ge to Ge distance is typically 0.2 mm).
The four crystals are mounted in a common cryostat with tapered squared and cap. Distance between cap and crystal has been reduced to 3.5 mm to improve the solid angle.
A major advantage of a CLOVER detector consists of its high absorption efficiency : results are not only four times those obtained with a single crystal but, as crystals are mounted without any additional absorbing material, the full energy of a photon Compton scattered and absorbed in a second crystal can be determined. The full energy peak can be obtained by summing ("add-back") the energies deposited in the N segments firing.
The "Add-back" efficiency is then superior to the sum of the four individual efficiencies.
In the EUROGAM CLOVER detector (dia. = 50 mm, l = 70 mm), the mean relative efficiency (epw)m of a crystal is between 20 and 21 %, whereas the total relative efficiency (epw)tot in 'addback' mode is between 120 and 130 %.
The energy resolution of the four shaped crystals is typically less than 2.1 keV at 1.33 MeV and 1.05 keV at 122 keV. In add-back mode, the energy resolution is still excellent : 2.3 keV at 1.33 MeV.
Similar resolutions have been obtained with larger CLOVER than the EUROGAM detector.
The arrangement of several small crystals induces other advantages in comparison with a large single crystal :
The reduction of the crystal opening angle permits a Doppler broadening reduction.
The sensitivity to neutron damages is also reduced.
The timing response of each individual crystal, measured with a 60Co source in coincidence with a small BaF2 scintillator, is very good. Average FWHM is 5 to 6 ns and FWTM/FWHM is about 3.0 for a 50 keV energy threshold and a DFC delay of 30 ns.
The CLOVER can also be used as polarimeters due to the presence of four crystals.
The CLOVER detector offer has regularly been improved during the 10 last years; first by increasing the total CLOVER efficiency with the use of crystals of larger volume, then by improving the granularity of the device to enhance the detector resolving power.
Granularity qualifies the number of independent cells constituting the detector. First CLOVERs had a granularity of 4 crystals. A 2 or 4 fold longitudinal crystal segmentation drastically increases that granularity.
Such detectors allow an important reduction of gamma ray broadening due to the Doppler effect. Moreover, the use of internal and external contacts of the crystal (in case of detector segmentation) gives us an interaction position information:
Vertically and transversally by analyzing signals induced by the mirror charge
Radially, by making a pulse shape analysis
Accurate location of the interaction points allows not only reduction of Doppler broadening, but also gamma ray tracking in the detector.
Some cryostats have been designed to optimize the total resolving power by adding a BGO detector ('back catcher') at the rear face of the crystal.
Moreover, the maintenance of such tools has been simplified for the users: easy access to the cooled efficiency transistor offers on site replacement possiblity.
CLOVER detector dewars are smaller and allow:
compact arrangement covering nearly 4P,
positioning in all directions
… while ensuring a full 1-day filling autonomy.
Other clovers have been designed, the 'well' type for example, allowing measurement of large samples with an angular covering of almost 4P:
samples with an angular covering of almost 4P :
Useful diameter :
35 mm High resolution High absorption efficiency at the middle of the well.
Company Details
For over 35 years, the name Canberra has been known for world
class nuclear measurement equipment and
services. Now... meet the new
Canberra.
... more
| More Products of this Company: |
ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, ADM606M Multi-purpose Radiation Monitor, AFT Research Amplifier - Model 2025, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, Alpha Spectrometers and Accessories, AMP/TSCA - Model 2015A, Arrangement of 2 or more Germanium Detectors, BARA 31 Gamma Alarm Beacon, Bin/Power Supply - Model 2000/2100, CAM110FF Series Continuous Air Monitors, Charge Amplifiers for Bonner Multisphere Systems, Charge Amplifiers for Neutron Scattering, Digital Signal Processor - Model 2060, Eclipse - Control and Analysis Software for S5XLB and LB5500 Systems, Edge/Crossover Timing Single Channel Analyzer - Model 2037A, Front Opening Split-Top Shield - Model 767, G64 Gamma Monitor, Gamma Analyst Integrated Gamma Spectromete, Ge Encapsulated Detectors, Ge Segmented Coaxial Detectors, Geiger Mueller Detectors - GP Series, Geiger-Mueller (GM) Tubes, iCAM Alpha/Beta Air Monito, ICB Programmable Digital Signal Processor - Model 9660, iMatic Gas-less Automatic Alpha/Beta Counting System, iSolo Gas-less Manual Alpha / Beta Counting System, LB4100 Multi-Detector Low Background Alpha/Beta Counting System, LB5500 Large Area Automatic Low Background Alpha/Beta Counting System, Linear Ratemeter - Model 2081, Model 512 - Dual Counter/Timer, Model 8224 Analog Multiplexer, Model 8715 - Analog-to-Digital Converte, Model 9635 - ICB Programmable ADC, Model Calibrator/M Semi-Automatic Calibration and Check Bench, Networked Continuous Air Monitor (NetCam), Neutron Detectors - NP Series, PGM102 Portable Gas Monitor, Photomultiplier Tube Base/Preamplifier - Model 2007/2007P, Scintillation Detectors - Model 802, Series 5 APC Console Based Automatic Alpha/Beta/Gamma Counting Systems, Series 5E Console-Based Automatic Low Background Alpha/Beta Counting System, Series 5XLB Automatic Low Background Alpha/Beta Counting System, Si(Li) Charged Particle Detectors with Transmission Mounts, Si(Li) Segmented X-ray Detectors, Silicon (Li) Detector Systems, Spectroscopy Amplifier - Model 2026, Standard PIPS Detectors, TAM Series Tritium Air Monitor, X-PIPS Detector |
| Related Products: |
296 ScintiPack Photomultiplier Base with Preamp and HV Supply, 460 Delay Line Amplifier, 474 Timing Amplifier, 570 AMPLIFIER, 572A AMPLIFIER, 590A AMPLIFIER AND TIMING SINGLE CHANNEL ANALYZER, 671 SPECTROSCOPY AMPLIFIER, 673 Spectroscopy Amplifier and Gated Integrato, 863 QUAD TIMING FILTER AMPLIFIER, 9327 1-GHz Amplifier and Timing Discriminator, ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, ADM606M Multi-purpose Radiation Monitor, AFT Research Amplifier - Model 2025, ALPHA (NORM) CONTAMINATION IN PIPES, TOOLS AND OBJECTS, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, Alpha Spectrometers and Accessories, ALPHA SURFACE CONTAMINATION, AMP/TSCA - Model 2015A, Arrangement of 2 or more Germanium Detectors, BARA 31 Gamma Alarm Beacon, Bin/Power Supply - Model 2000/2100, CAM110FF Series Continuous Air Monitors, Charge Amplifiers for Bonner Multisphere Systems |
|
|
|
|