Login:   Password:
Not Register?    Sign Up NOW!
Date: 02 December 2008
Google
 
Series 5 APC Console Based Automatic Alpha/Beta/Gamma Counting Systems  
Search Country   Reset filter

Series 5 APC Console Based Automatic Alpha/Beta/Gamma Counting Systems

Product Name: Series 5 APC Console Based Automatic Alpha/Beta/Gamma Counting Systems

Product Description

Series 5 APC Console Based Automatic Alpha/Beta/Gamma Counting Systems
Features
Automatic single detector systems 
Offers standard 5.7 cm (2.25 in.) or 3.2 cm (1.25 in.) gas flow proportional detector or optional ZnS or GM detectors 
Uses Mini GasStat for gas flow systems 
Fifty planchet sample changer with optional 100 sample capacity 
Performs automatic full system calibration 
Has multiple data output modes 
Universal auto-sensing power supply 
Utilizes Flash Card memory storage 
Stat Count for priority samples 
Requires no installation 

Description
Designed for the Application

The Tennelec Series 5 APC is a console-based system designed to screen samples that do not require traditional low background performance. The Series 5 APC is an automatic, lightweight and easy to operate system making it perfect for applications that require only a basic smear counter but still have large throughput needs. The added expense of a low background system is eliminated in the Series 5 APC making it an ideally affordable solution for the laboratory while aiding in the prevention of contamination of more sensitive instrumentation. Since the S 5 APC is offered in several different models with an assortment of different detectors, finding one to fit your needs is easy. Likewise, the Series 5 APC has the same user interface across all models eliminating the learning curve when using a combination of Series 5 console based units.
Configured to Meet Your Needs

The Series 5 APC is factory configured with different detectors for specific counting requirements. A gas flow version is available in 5.7 cm (2.25 in.) or 3.2 cm (1.25 in.) models and provides the same alpha/beta counting modes as the other Series 5 gas flow systems: alpha only, alpha/beta simultaneous, and alpha-then-beta modes. The Zinc Sulfide (ZnS) scintillation detector is available for applications that require alpha only counting. A Geiger Muller (GM) detector is available for those who have gross counting needs. Since the ZnS and GM models do not require counting gas, they are advantageous for applications where gas is not readily available. 
Time Proven Reliability

The sample changer of the Tennelec Series 5 family is time and field proven. The highly reliable design of the automated sample changer transports and counts samples day after day providing worry free operation.
Mini-Gas Stat 

The Series 5 APC incorporates a microprocessor controlled gas monitoring and control system for gas flow detector models called Mini Gas Stat. Mini Gas Stat eliminates the need to adjust manual flow meters. The Series 5 APC hardware senses when the system is not counting samples, and automatically reduces the gas flow rate to a low quiescent flow to maintain detector gas quality. This prevents atmospheric impurities from diffusing into the detector and causing questionable results. When the user starts a count, Mini Gas Stat automatically purges the detector and resets the flow rate to normal.


Mini Gas Stat effectively increases the useful life of the gas supply, thereby reducing the frequency of instrument reverification, saving time and improving the quality of counting data.

Stat Count

How many times have rush samples come into the laboratory only to interrupt the current samples counting? No electronic record is generated showing that a batch was interrupted. Using Stat Count, the user can now interrupt samples the automatic way. Just choose a group plate, load the samples, select Stat Count and walk away. When the rush samples are complete, the instrument will return to the interrupted sample and resume counting. The interruption is documented on the report with a date and time showing a routine group was interrupted.
Multiple Data Output Modes

The Series 5 APC can send data directly to a printer, serial port, or Flash Card, separately or simultaneously. Data can be transmitted as each sample is counted in line by line mode or when a group of samples is completed. Combined with the Stat Count feature, line by line output to a printer allows for immediate documentation of priority sample activity.

Quick Set-up with LB-Link

Using a specially designed PC application called LB-Link, procedures, reports, printer set-up, source entry, security set-up and much more can now be done in the convenience of your office through a PC. Using the Flash Card feature of the S5 APC, simply save the file structure of the counting unit to the Flash Card via a menu option. Insert the Flash card into the PC and launch LB-Link. The simple and easy to use interface will allow quick and easy set-up of all parameters and editing if necessary. When complete, simply download the information from the FlashCard to one or multiple instruments, and you are up and running with your customized set-up parameters.

Company Details

For over 35 years, the name Canberra has been known for world class nuclear measurement equipment and services. Now... meet the new Canberra.

... more

More Products of this Company: ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, ADM606M Multi-purpose Radiation Monitor, AFT Research Amplifier - Model 2025, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, Alpha Spectrometers and Accessories, AMP/TSCA - Model 2015A, Arrangement of 2 or more Germanium Detectors, BARA 31 Gamma Alarm Beacon, Bin/Power Supply - Model 2000/2100, CAM110FF Series Continuous Air Monitors, Charge Amplifiers for Bonner Multisphere Systems, Charge Amplifiers for Neutron Scattering, Digital Signal Processor - Model 2060, Eclipse - Control and Analysis Software for S5XLB and LB5500 Systems, Edge/Crossover Timing Single Channel Analyzer - Model 2037A, Front Opening Split-Top Shield - Model 767, G64 Gamma Monitor, Gamma Analyst Integrated Gamma Spectromete, Ge Clover Detectors, Ge Encapsulated Detectors, Ge Segmented Coaxial Detectors, Geiger Mueller Detectors - GP Series, Geiger-Mueller (GM) Tubes, iCAM Alpha/Beta Air Monito, ICB Programmable Digital Signal Processor - Model 9660, iMatic Gas-less Automatic Alpha/Beta Counting System, iSolo Gas-less Manual Alpha / Beta Counting System, LB4100 Multi-Detector Low Background Alpha/Beta Counting System, LB5500 Large Area Automatic Low Background Alpha/Beta Counting System, Linear Ratemeter - Model 2081, Model 512 - Dual Counter/Timer, Model 8224 Analog Multiplexer, Model 8715 - Analog-to-Digital Converte, Model 9635 - ICB Programmable ADC, Model Calibrator/M Semi-Automatic Calibration and Check Bench, Networked Continuous Air Monitor (NetCam), Neutron Detectors - NP Series, PGM102 Portable Gas Monitor, Photomultiplier Tube Base/Preamplifier - Model 2007/2007P, Scintillation Detectors - Model 802, Series 5E Console-Based Automatic Low Background Alpha/Beta Counting System, Series 5XLB Automatic Low Background Alpha/Beta Counting System, Si(Li) Charged Particle Detectors with Transmission Mounts, Si(Li) Segmented X-ray Detectors, Silicon (Li) Detector Systems, Spectroscopy Amplifier - Model 2026, Standard PIPS Detectors, TAM Series Tritium Air Monitor, X-PIPS Detector
Related Products: 265A Photomultiplier Base, 296 ScintiPack Photomultiplier Base with Preamp and HV Supply, 414A Fast Coincidence, 427A Delay Amplifier, 439 Digital Current Integrator, 460 Delay Line Amplifier, 474 Timing Amplifier, 533 DUAL SUM AND INVERT AMPLIFIER, 542 Linear Gate and Stretcher, 570 AMPLIFIER, 572A AMPLIFIER, 590A AMPLIFIER AND TIMING SINGLE CHANNEL ANALYZER, 671 SPECTROSCOPY AMPLIFIER, 673 Spectroscopy Amplifier and Gated Integrato, 863 QUAD TIMING FILTER AMPLIFIER, 9302 AMPLIFIER DISCRIMINATOR, 9327 1-GHz Amplifier and Timing Discriminator, ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, ADM606M Multi-purpose Radiation Monitor, AFT Research Amplifier - Model 2025, ALPHA (NORM) CONTAMINATION IN PIPES, TOOLS AND OBJECTS, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, Alpha Spectrometers and Accessories
Home | Members.Benefit | Privacy.Policy | Bookmark.This.Page | Contact.Us
© 2006 - 2007 4engr. All Rights reserved |Recommended Engineering Sites:| Center for Respect of Life and Environment | Internet Dictionary|Enginering intent(Engineering Events) | Map Archive