Product Name: LB5500 Large Area Automatic Low Background Alpha/Beta Counting System
Product Description

Features
Automatic single 5 inch detector, ultra-low background counting system
Enhanced low background capability
Gas Stat digital gas conservation and monitoring system
Fifty planchet sample changer
Low background passive shielding
True bench-top model with reduced system footprint and integrated portable cart
High performance 12.7 cm (5.0 in.) gas flow detector with ultra thin window 80 mg/cm2; one inch detector option
Advanced electronic diagnostics continuously monitor operating conditions
Universal auto-sensing power supply
Coded positive sample carrier identification
Optional external bar code reader
CE compliant
Description
Large Area Counting System
The Tennelec LB5500 is designed for counting large samples, up to 12.7 cm (5 in.) in diameter. Built on the same foundation of quality and innovation as other Series 5 systems, the Tennelec LB5500 offers low background performance for applications requiring a large area counting system. The added capabilities of Eclipse Control and Analysis Software make the LB5500 a state-of-the-art counting system that easily integrates into today’s count room. Specially designed detector windows provide the Tennelec LB5500 with excellent counting efficiency exceeding current regulatory requirements.
Whether counting large area air filters or for methods requiring additional sample amounts, the LB5500 is the system of choice.
Enhanced Low Background and Productivity – Simply the Best
Due to increasing environmental regulations to reach lower detection limits, sample count times have increased reducing the overall sample throughput in the laboratory. The Tennelec LB5500 incorporates new technology to reduce system background and increase sample throughput. Using an improved guard detector, the system sensitivity for high energy, cosmic background is increased, enabling the anti-coincidence circuitry to detect and reject more spurious background events.
The beta background for the LB5500 has been reduced by as much as 25% over older systems. Beta backgrounds as low as 3.0 cpm can be achieved. This means that the system can count almost twice as many samples for a given detection limit as a counter with a beta background of 5.0 cpm.
Passive Metric Shield
Using a graded shielding system, the LB5500 counts large area samples with more accuracy than any other low background counter. The passive shield system provides 10 cm (4 in.) of low background lead surrounding the detector. The shield comprises standard 5 x 10 x 20 cm metric lead bricks which weigh no more than 12 kg (25 lb) each for safety and ease of assembly. This lead is secured within a steel housing for further safety and to ensure minimal shifting.
Time Proven Reliability
The sample changer of the LB5500 is time and field proven. The highly reliable design of the automated sample changer transports and counts samples day after day providing worry free operation. When work counts and time is precious, count on a Tennelec system to deliver results and reliability.
Ultra-Thin Detector Windows
The standard gas flow detector of the Tennelec Series 5 family of systems incorporates a high performance pancake-style 12.7 cm (5.0 in.) detector. The entrance window of the detector is made with state-of-the-art technology and special materials to provide the highest counting efficiency and the lowest alpha background of any counter. Standard detector windows are 80 mg/cm2 with 500 mg/cm2 window as an option.
Positive Sample Identification and Bar Code – The Advantage
Today’s changing requirements demand sample identification that is maintained through the counting data. Data defensibility is a priority.
The Tennelec LB5500 incorporates unique carrier and sample identification systems to maintain chain-of-custody. An optional handheld bar code scanner allows input of sample information directly into the Eclipse software for improved chain-of-custody verifiability.
As the sample is counted, the carrier ID or sample bar code are automatically captured by the Eclipse software and stored with the sample count data forming the missing link in sample custody in the count room.
Tennelec sample carriers are washable for easy cleaning and decontamination. Each carrier is permanently coded with a unique number that is non-removable after numerous washings.
Circuitry So Advanced, It Thinks for Itself
The advanced electronics package of the Series 5 family of counting systems provides the most advanced control and monitoring system available. The Series 5 incorporates hardware diagnostics which continuously monitor internal and external parameters including gas pressure and flow, system voltage, power distribution, sample and guard counts, and other system critical parameters. The user is alerted on the front panel if any of these parameters fall below normal operation thresholds. This allows you to take immediate action when a problem arises.
Circuitry So Advanced, It Thinks for Itself
The advanced electronics package of the Series 5 family of counting systems provides the most advanced control and monitoring system available to assure accurate results. The Series 5 incorporates hardware diagnostics which continuously monitor internal and external parameters including gas pressure and flow, system voltage, power distribution, sample and guard counts, and other system critical parameters. The user is alerted on the front panel if any of these parameters fall below normal operation thresholds.
Human Factor Engineering
Often computer controlled analytical equipment requires additional laboratory space for the computer system and peripherals. The LB5500 answers that problem with an integrated mobile cart that provides all of the support necessary for the gas tank, computer system, monitor and printer. The articulating monitor support provides adjustable viewing angles without requiring additional space on the desktop. The retractable shelf opens to hold printer and supplies.
The LB5500 is designed to be a completely integrated, self contained counting system. The LB5500 has the industry’s smallest footprint for a large area counting system, so it takes up less space compared to other large area systems.
Company Details
For over 35 years, the name Canberra has been known for world
class nuclear measurement equipment and
services. Now... meet the new
Canberra.
... more
| More Products of this Company: |
ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, ADM606M Multi-purpose Radiation Monitor, AFT Research Amplifier - Model 2025, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, Alpha Spectrometers and Accessories, AMP/TSCA - Model 2015A, Arrangement of 2 or more Germanium Detectors, BARA 31 Gamma Alarm Beacon, Bin/Power Supply - Model 2000/2100, CAM110FF Series Continuous Air Monitors, Charge Amplifiers for Bonner Multisphere Systems, Charge Amplifiers for Neutron Scattering, Digital Signal Processor - Model 2060, Eclipse - Control and Analysis Software for S5XLB and LB5500 Systems, Edge/Crossover Timing Single Channel Analyzer - Model 2037A, Front Opening Split-Top Shield - Model 767, G64 Gamma Monitor, Gamma Analyst Integrated Gamma Spectromete, Ge Clover Detectors, Ge Encapsulated Detectors, Ge Segmented Coaxial Detectors, Geiger Mueller Detectors - GP Series, Geiger-Mueller (GM) Tubes, iCAM Alpha/Beta Air Monito, ICB Programmable Digital Signal Processor - Model 9660, iMatic Gas-less Automatic Alpha/Beta Counting System, iSolo Gas-less Manual Alpha / Beta Counting System, LB4100 Multi-Detector Low Background Alpha/Beta Counting System, Linear Ratemeter - Model 2081, Model 512 - Dual Counter/Timer, Model 8224 Analog Multiplexer, Model 8715 - Analog-to-Digital Converte, Model 9635 - ICB Programmable ADC, Model Calibrator/M Semi-Automatic Calibration and Check Bench, Networked Continuous Air Monitor (NetCam), Neutron Detectors - NP Series, PGM102 Portable Gas Monitor, Photomultiplier Tube Base/Preamplifier - Model 2007/2007P, Scintillation Detectors - Model 802, Series 5 APC Console Based Automatic Alpha/Beta/Gamma Counting Systems, Series 5E Console-Based Automatic Low Background Alpha/Beta Counting System, Series 5XLB Automatic Low Background Alpha/Beta Counting System, Si(Li) Charged Particle Detectors with Transmission Mounts, Si(Li) Segmented X-ray Detectors, Silicon (Li) Detector Systems, Spectroscopy Amplifier - Model 2026, Standard PIPS Detectors, TAM Series Tritium Air Monitor, X-PIPS Detector |
| Related Products: |
265A Photomultiplier Base, 296 ScintiPack Photomultiplier Base with Preamp and HV Supply, 414A Fast Coincidence, 427A Delay Amplifier, 439 Digital Current Integrator, 460 Delay Line Amplifier, 474 Timing Amplifier, 533 DUAL SUM AND INVERT AMPLIFIER, 542 Linear Gate and Stretcher, 570 AMPLIFIER, 572A AMPLIFIER, 590A AMPLIFIER AND TIMING SINGLE CHANNEL ANALYZER, 671 SPECTROSCOPY AMPLIFIER, 673 Spectroscopy Amplifier and Gated Integrato, 863 QUAD TIMING FILTER AMPLIFIER, 9302 AMPLIFIER DISCRIMINATOR, 9327 1-GHz Amplifier and Timing Discriminator, ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, ADM606M Multi-purpose Radiation Monitor, AFT Research Amplifier - Model 2025, ALPHA (NORM) CONTAMINATION IN PIPES, TOOLS AND OBJECTS, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, Alpha Spectrometers and Accessories |
|
|
|
|