Login:   Password:
Not Register?    Sign Up NOW!
Date: 02 December 2008
Google
 
iSolo Gas-less Manual Alpha / Beta Counting System  
Search Country   Reset filter

iSolo Gas-less Manual Alpha / Beta Counting System

Product Name: iSolo Gas-less Manual Alpha / Beta Counting System

Product Description

Features
Portable, manual, single- sample alpha/beta counter
Automatically identifies and compensates for radon, thoron and progeny interference
PIPS® silicon gas-less detector
Developed primarily for air filter analysis
NiMH battery power for 10 hours or more
Universal, auto-sensing power supply
Optional scintillation cosmic guard detector 
Compatible with essentially all filter types and multiple sizes
Compatible with iLink™ iSeries™ Communications Software for remote setup and download of data to a computer
CE compliant

Description

The CANBERRA iSolo® is a portable, firmware based, single-sample, manual, gas-less alpha/beta counter designed specifically for the analysis of air filters and smear or swipe samples. The iSolo discriminates both radon and thoron and their progeny from transuranic and fission product materials on the samples. It weighs slightly less than 19 pounds, even with an optional guard detector installed; uses a solid state silicon PIPS® detector for alpha and beta detection; can be operated for 10 hours or more with internal batteries and is totally self contained. The iSolo represents a major technological breakthrough in air filter analysis.
The Problem is Radon

Counting air samples from either CAM units or stationary samplers can pose serious problems for the health physicist. Why? Radon, thoron and their respective progeny emit alpha particles with energies from 6.0 MeV to 8.78 MeV. The low energy peak tails from these detected alphas mask the spectral region where alphas from transuranic (uranium, plutonium, americium and curium) alphas would be (See Figure 1). Even the smallest amount of radon/thoron interference on a filter paper can cause ‘falsely’ elevated DAC values. Radon/thoron is the problem, but the real difficulty is knowing when the values are false – caused only by radon/thoron interference and not a plutonium or uranium release.

The Traditional Approach

The traditional approach for determining the activity of long-lived radionuclides present in air is to sample a measured volume of air through a filter, generally in a stationary air sampler. The filter is transported to the laboratory and counted on a gas flow or similar low background alpha/beta counting system. If the reportable alpha DAC value is above maximum permissible limits and radon/thoron is suspected, the filter is quickly counted again. By this time workers have remained in the area for several hours, without respirator protection. When the results from the second count show that the alpha DAC value is still above permissible limits, workers are evacuated from the work area until a determination is made by the lead technician on shift. By the time a ratio calculation is performed and the activity is deemed to be from radon/thoron interference, several more hours have passed. Time is money and downtime is expensive; but employee safety must always come first, and ratios are not always correct. Days may be needed before the alpha activity reported is absolutely identified as radon, thoron and their progeny.

The iSolo Approach

The CANBERRA iSolo solves this problem with a new and innovative approach. Gone are the days of waiting for hours or even days for radon/thoron interferences to decay away before an actual activity is known. With the iSolo, you will know within minutes if the alpha activity is due to transuranic or fission product material or naturally occurring radon and thoron. A pulse height spectrum, similar to the one shown in Figure 2, is acquired in a multichannel analyzer in the iSolo. 

A series of peak evaluations are performed on the original acquired spectrum. When all of the corrections are made, a residual spectrum, similar to the one shown in  (shown in red) results and from this residual spectrum the iSolo reports radon compensated, true alpha and beta activity on the front panel LCD display. 

Not only are the numerical results shown on the iSolo’s screen, but the 256 channel spectra of both the original and radon compensated data can be seen as well. (See Figures 4 and 5). The spectra can be viewed in linear or log scale, and the scale can be set automatically or manually by the user. The X axis of a compensated spectrum is shown in the middle of the display to accommodate channels with negative data. 

Complete Solution

The CANBERRA iSolo is a complete solution for the analysis of filter and filter type samples. The iSolo, unlike any other alpha/beta counter, is based on the same technology as CANBERRA’s iCAM. The iSolo provides reliable measurements of transuranic and fission product activity on filter samples in the presence of radon/thoron interferences. Using a patent pending technique, the iSolo applies auto-adaptive spectrometric compensation for the radon/thoron interferences. 

The iSolo radon/thoron compensation algorithm adjusts to all types of filter media from glass fiber filter media for smear analysis to Millipore® membrane type filter media for air sampling. The iSolo adapts to these different filter media types automatically. No additional calibrations or special instrument settings are required. The iSolo lets health physics technicians focus on their job without calculators, manual ratio calculations, downtime, and guesswork. Two built-in, operator-adjustable alpha and beta alarm levels are provided to alert the operator when a critical limit has been exceeded. The operator can then proceed quickly with the necessary actions without the added worry of making a mistake. An optional iSolo anti-coincidence guard detector provides rejection of external gamma and cosmic radiation to minimize the overall system alpha and beta background. 

The anti-coincidence guard detector utilizes a customized ‘wrap around’ plastic scintillator. The guard detector surrounds the sample detector optimizing the rejection of low angle external gamma and cosmic events. The light pulses generated within the scintillator are coupled to a photomultiplier tube where the light is converted into an electrical signal that is used to anti-coincidence gate the data collection of PIPS sample detector events. When throughput and sensitivity are essential, the iSolo with optional guard is unsurpassed among other portable alpha/beta counters. 

The iSolo provides the system operator with gross alpha/beta results, but that is only the beginning of what it does. There is absolutely no spillover to compensate for. Pulses from detected charged particles are sorted by energy. A lower level discriminator is set at 125 keV and any particle with energy greater than this threshold but less than 2.2 MeV is identified as a beta. A particle with energy greater than 3 MeV and less than or equal to 9.6 MeV is identified as an alpha. The 3 MeV to 6.4 MeV portion of the alpha region is further divided into three overlapping regions; a uranium region, an americium/plutonium region and a curium region. These regions allow the user to reasonably determine which nuclide is present in a sample if a high compensated alpha result is encountered. The following regions may be selected to be reported on the iSolo hardcopy printout. Energy values are approximate. 
Total Alpha Region: 3.0 MeV to 9.6 MeV
Uranium Region: 3.0 MeV to 5.0 MeV
Uranium, Am and Pu Region: 3.0 MeV to 5.6 MeV
Curium Region: 3.0 MeV to 6.4 MeV
Total Beta Region: 125 keV to 2.2 MeV
Standalone Instrument – No Computer

The iSolo is a firmware based instrument and does not require a computer to set up or operate it. The entire program is stored in flash memory. New programs may be downloaded as a file via HyperTerminal™ using the RS-232C interface. There are no PROMs to change and no housings to remove to get to them. The entire process to upgrade the iSolo program takes less than five minutes. 
iLink iSeries Communications Software

If computer control and/or the ability to download iSolo results into a Microsoft® SQL Server database are desired, iLink iSeries Communications Software is available for this purpose. iLink provides the operator of iSolo systems the ability to program the majority of the iSolo features with a computer, rather than through the use of front panel buttons. iLink also includes an embedded version of the Microsoft SQL Server database for the storage of iSolo data.

All iLink functions are controlled via an intuitive graphical user interface. These functions include the ability to enter sources, enter sample and guard detector voltages and thresholds, setup the system printer and print mode, edit or create iSolo report templates, establish iLink and iSolo securities, create User, Calibration and QC procedures, backup and restore iSolo system personalities, and export data in comma separated (CSV) or Tab-Delimited formats

Company Details

For over 35 years, the name Canberra has been known for world class nuclear measurement equipment and services. Now... meet the new Canberra.

... more

More Products of this Company: ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, ADM606M Multi-purpose Radiation Monitor, AFT Research Amplifier - Model 2025, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, Alpha Spectrometers and Accessories, AMP/TSCA - Model 2015A, Arrangement of 2 or more Germanium Detectors, BARA 31 Gamma Alarm Beacon, Bin/Power Supply - Model 2000/2100, CAM110FF Series Continuous Air Monitors, Charge Amplifiers for Bonner Multisphere Systems, Charge Amplifiers for Neutron Scattering, Digital Signal Processor - Model 2060, Eclipse - Control and Analysis Software for S5XLB and LB5500 Systems, Edge/Crossover Timing Single Channel Analyzer - Model 2037A, Front Opening Split-Top Shield - Model 767, G64 Gamma Monitor, Gamma Analyst Integrated Gamma Spectromete, Ge Clover Detectors, Ge Encapsulated Detectors, Ge Segmented Coaxial Detectors, Geiger Mueller Detectors - GP Series, Geiger-Mueller (GM) Tubes, iCAM Alpha/Beta Air Monito, ICB Programmable Digital Signal Processor - Model 9660, iMatic Gas-less Automatic Alpha/Beta Counting System, LB4100 Multi-Detector Low Background Alpha/Beta Counting System, LB5500 Large Area Automatic Low Background Alpha/Beta Counting System, Linear Ratemeter - Model 2081, Model 512 - Dual Counter/Timer, Model 8224 Analog Multiplexer, Model 8715 - Analog-to-Digital Converte, Model 9635 - ICB Programmable ADC, Model Calibrator/M Semi-Automatic Calibration and Check Bench, Networked Continuous Air Monitor (NetCam), Neutron Detectors - NP Series, PGM102 Portable Gas Monitor, Photomultiplier Tube Base/Preamplifier - Model 2007/2007P, Scintillation Detectors - Model 802, Series 5 APC Console Based Automatic Alpha/Beta/Gamma Counting Systems, Series 5E Console-Based Automatic Low Background Alpha/Beta Counting System, Series 5XLB Automatic Low Background Alpha/Beta Counting System, Si(Li) Charged Particle Detectors with Transmission Mounts, Si(Li) Segmented X-ray Detectors, Silicon (Li) Detector Systems, Spectroscopy Amplifier - Model 2026, Standard PIPS Detectors, TAM Series Tritium Air Monitor, X-PIPS Detector
Related Products: 265A Photomultiplier Base, 296 ScintiPack Photomultiplier Base with Preamp and HV Supply, 414A Fast Coincidence, 427A Delay Amplifier, 439 Digital Current Integrator, 460 Delay Line Amplifier, 474 Timing Amplifier, 533 DUAL SUM AND INVERT AMPLIFIER, 542 Linear Gate and Stretcher, 570 AMPLIFIER, 572A AMPLIFIER, 590A AMPLIFIER AND TIMING SINGLE CHANNEL ANALYZER, 671 SPECTROSCOPY AMPLIFIER, 673 Spectroscopy Amplifier and Gated Integrato, 863 QUAD TIMING FILTER AMPLIFIER, 9302 AMPLIFIER DISCRIMINATOR, 9327 1-GHz Amplifier and Timing Discriminator, ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, ADM606M Multi-purpose Radiation Monitor, AFT Research Amplifier - Model 2025, ALPHA (NORM) CONTAMINATION IN PIPES, TOOLS AND OBJECTS, Alpha Analyst Integrated Alpha Spectrometer, Alpha Beta Environmental Continuous Air Monitor (ECAM), Alpha Sentry CAM, Alpha Spectrometers and Accessories
Home | Members.Benefit | Privacy.Policy | Bookmark.This.Page | Contact.Us
© 2006 - 2007 4engr. All Rights reserved |Recommended Engineering Sites:| Center for Respect of Life and Environment | Internet Dictionary|Enginering intent(Engineering Events) | Map Archive