Product Name: 572A AMPLIFIER
Product Description
General-purpose amplifier for energy spectroscopy with all types of detectors
Built-in pile-up rejector and gated BLR with automatic thresholds for excellent performances at high counting rates
Unipolar and bipolar outputs
Active filter networks with wide range of time constants
Wide gain range
The ORTEC Model 572A Amplifier is ideally suited for use with germanium detectors, silicon charged-particle detectors, proportional counters, scintillation counters, and pulsed ion chambers. It includes an automatic gated baseline restorer and built-in pile-up rejector to provide exceptionally stable performance over a very wide dynamic range. System resolution is nearly independent of input counting rate.
The gated baseline restorer (BLR) includes a discriminator that operates the sensing circuits that normally establish the baseline reference of the MCA. Performance of the spectrometer depends on the precision of the setting of the BLR threshold. The Model 572A offers the convenience of an automatic threshold control, which typically gives as good or better results than those the most experienced operator could achieve manually. The gate logic generates a Busy signal that can be used for dead-time correction.
The active filter networks permit the Model 572A to generate very symmetrical unipolar outputs with optimum signal-to-noise ratios over a wide range of time constants. The instrument also provides a bipolar output for timing and gating applications.
Any dc drift in an amplifier output causes spectrum broadening. The excellent dc stability of the Model 572A eliminates spectrum broadening caused by dc drift and ensures that the high resolution capability of germanium detectors is realized.
Pile-Up Rejector: The pile-up rejection circuit incorporated into the Model 572A generates an inspection period immediately following every signal equal to the duration of the Busy output. If a second event were to occur within this inspection interval, an inhibit signal, INH Output, would be generated to gate-off the MCA and thus discard the distorted amplifier output. Figure 2 shows the background reduction that takes place ina gamma ray spectrum as pile-up rejectionis used. Figure 3 illustrates the timing relationship between the amplifier input, output, and pile-up rejector logic signals.
Company Details
From its inception as a small enterprise founded by scientists and engineers from the Oak Ridge National Laboratory, our business and reputation for excellence in scientific instrumentation have grown substantially. Along with that growth came... more
| More Products of this Company: |
265A Photomultiplier Base, 296 ScintiPack Photomultiplier Base with Preamp and HV Supply, 414A Fast Coincidence, 427A Delay Amplifier, 439 Digital Current Integrator, 460 Delay Line Amplifier, 474 Timing Amplifier, 533 DUAL SUM AND INVERT AMPLIFIER, 542 Linear Gate and Stretcher, 570 AMPLIFIER, 590A AMPLIFIER AND TIMING SINGLE CHANNEL ANALYZER, 671 SPECTROSCOPY AMPLIFIER, 673 Spectroscopy Amplifier and Gated Integrato, 863 QUAD TIMING FILTER AMPLIFIER, 9302 AMPLIFIER DISCRIMINATOR, 9327 1-GHz Amplifier and Timing Discriminator, Chemical Weapons Assay, CO4020 Quad 4-Input Logic Unit, FTA820A Octal Fast Timing Amplifier, GG8020 Octal Gate and Delay Generator, HM413 CAMAC FERAbus Histogramming Memory, MDS Multi-detector Manual System, MPC-2000 & MPC-2000-PC Desktop Alpha/Beta Counter, Positron Lifetime Picosecond Timing System, WPC-9450 Automatic 5 System, WPC-9550 Automatic Low Background System |
| Related Products: |
265A Photomultiplier Base, 296 ScintiPack Photomultiplier Base with Preamp and HV Supply, 427A Delay Amplifier, 460 Delay Line Amplifier, 474 Timing Amplifier, 533 DUAL SUM AND INVERT AMPLIFIER, 542 Linear Gate and Stretcher, 570 AMPLIFIER, 590A AMPLIFIER AND TIMING SINGLE CHANNEL ANALYZER, 671 SPECTROSCOPY AMPLIFIER, 673 Spectroscopy Amplifier and Gated Integrato, 863 QUAD TIMING FILTER AMPLIFIER, 9302 AMPLIFIER DISCRIMINATOR, 9327 1-GHz Amplifier and Timing Discriminator, ACHNP97 & ACHNA98 Industrial Charge Amplifiers for Helium-3 Detectors, AFT Research Amplifier - Model 2025, Alpha Spectrometers and Accessories, AMP/TSCA - Model 2015A, Charge Amplifiers for Bonner Multisphere Systems, Charge Amplifiers for Neutron Scattering, Digital Signal Processor - Model 2060, Edge/Crossover Timing Single Channel Analyzer - Model 2037A, FTA820A Octal Fast Timing Amplifier, G64 Gamma Monitor, ICB Programmable Digital Signal Processor - Model 9660 |
|
|
|
|