Product Name: FHS-UV In-Line Filter Holder
Product Description
The FHS-UV In-Line Filter Holder is a low-cost spectrophotometric
accessory for fast, convenient absorbance/transmission measurements of optical
and other filters. Ocean Optics' FHS-UV In-Line Filter Holder is optimized for
UV-VIS-NIR (200 nm-2 µm) measurements.
The FHS-UV is $399.
The FHS-UV In-Line Filter Holder features a pair of 74-UV 5-mm diameter f/2
collimating lenses that maximize light throughput, as well as a manual
light-block wheel for dark readings. The Filter Holder acts as a simple yet
effective device for measuring filters. It also provides a convenient place to
accommodate filters for optical setups.
The In-Line Filter Holder accepts 1" round or any size >1/2" square optical
filters, up to ¼" (6 mm) in thickness. (For samples larger or thicker than our
In-Line Filter Holder can easily accommodate, users may wish to consider the
74-ACH Adjustable Collimating Lens Holder.) Plastic supports hold SMA-terminated
fibers steady.
When coupled to an Ocean Optics miniature fiber optic spectrometer, the In-Line
Filter Holder becomes a handy spectrophotometric tool for measuring
absorbance/transmission and other optical characteristics of filters. In fact,
the filter holder is a convenient alternative to more expensive or awkward
optical filter setups.
User's Tip
In an In-Line Filter Holder setup, the light that passes through the filter is
collimated. This makes it possible to measure either glass or interference
filters.
Specifications
FHS-UV
Collimating lenses (UV-VIS-NIR): |
» Quartz
lenses optimized from 200 nm-2 µm
» 5 mm diameter
» f/2 |
Collimating
lens termination: |
SMA 905 |
Filter slot: |
Accepts
filters 1" round or any size >1/2" square, up to 1/4" (6 mm) in thickness |
Base
material: |
Aluminum |
Size of light
beam reaching sample: |
~5 mm
(circular) |
Distance from
center of light beam to the sample: |
~0.575" |
Company Details
Ocean Optics is a leading supplier of solutions for optical sensing – fundamental methods of measuring and interpreting the interaction of light with matter. We enable diverse applications in medical and biological research, environmental... more
| More Products of this Company: |
74-series Lens Fixtures, 84-series Lens Fixture, 84-series Lens Fixture, Absorbing Glass Optical Filters, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, Adjustable Collimating Lens Holder, Cell for Capillary Electrophoresis, CFV-series FluoroVettes, Cosine Correctors for Emission Collection, CUV-ALL-UV 4-way Cuvette Holder for 1-cm Cuvettes, CUV-UV Holder for 1-cm Cuvettes, CUV-VAR Variable Pathlength Cuvette Holder, Cuvette Holder for 10-cm Cuvettes, CVD-UV and CVD-VIS Disposable Cuvettes, Diffuse Reflectance Standards, Electronic TTL Shutter, EviDot Semiconductor Nanocrystals, EviTag Water-stable Quantum Dots, FHSA-series Filter and Cuvette Holder, FIA-SIA-LOV Sequential Injection Analysis System, Fiber Optic Scanning Monochromator, Fiber Optic Variable Attenuator, Flow Cell Kit for Flow Injection Analysis, Flow Cell Kit for Flow Injection Analysis, Fluorescence Flow Cell, Fluorescence Flow Cell, Fluorescence Flow Injection Analysis System, Fluorescence Standard, FOIS-1 Fiber Optic Integrating Sphere, FOS-2x2-TTL Inline Fiber Optic Shutter, Gershun Tube Kit, ISP-I Integrating Spheres, ISP-R Integrating Spheres for Reflectance, ISP-REF Integrating Sphere, ISS-2 Integrated Sampling System, ISS-UV-VIS Integrated Sampling System, Longpass Flow Cell, LTP-V Long Trace Profilometer, MPM-2000 Optical Multiplexer, Optical Post Mounts, Posts and Assemblies, Positive Displacement Pump, Power Supply & Controller for LEDs, Precision Optical Flats, Quartz Cells, Reflection and Transmission Stage, Right-angle Collimating Lens Holder, Right-angle Collimating Lens Holder, Shear-plate Collimation Testers, Single-point Reflection Stage, SpectroPipetter for Microliter-volume Samples, Specular Reflection Standard, Low Reflectivity, Specular Reflection Standards, High Reflectivity, Temperature-regulated Cuvette Holder and Kits, Thin Film Reference Wafer, Variable-angle Reflection Sampling System, Wireless-G Cable Gateway Cable Modem with Built-In Wireless-G Router, Wireless-N Broadband Router: Start a Wireless Network With Up To 4X the Range and 12X the Speed!, Wireless-N Gigabit Gaming Router: Build a high-speed wireless network optimized for gaming!, Wireless-N Gigabit Router with Storage Link: Start a Wireless Network With Up To 4X the Range and 12X the Speed!, Wireless-N Home Router: Start a Wireless Network With Up To 3X the Range and 9X the Speed! |
| Related Products: |
Aircraft Maintenance, "HIGH PERFORMANCE GAS DRIVE" K-70, .965in Male - 1.25in Female Adapter, 1.25in Dropin Extension Tube with 1in Eye Piece Push Back, 1.25in Male - 2in Female Adapter, 1.25in Threadin Extension Tube with 1in Eye Piece Push Back, 1/3 & 3/4 HP Fixed Speed, Variable Length Turbines, 102 Envelope Machine, 108FPS PUMP SUCTION CONTROL VALVE, 1500 Series Door Holder Extension Rods, 16 Megapixel Camera With CameraLink Output, 16 Megapixel Camera With CameraLink Output, 19-Inch Widescreen Monitor, 2 HP Fixed Speed, Variable Length Turbines, 2 inch Extension Tube, 1.5" Push-Back, Drop-in, 2 inch Female to Schmidt Cassegrain Telescope Female Adapter Short, 2.5X CCD Compressor Lens, 2000-MTC Master Time/Program Clock, 2300RG MELLTRONICS DRIVES, 2600RG MELLTRONICS DRIVES, 265A Photomultiplier Base, 2700 MELLTRONICS DRIVES, 2in Dropin Extension Tube with 1in Eye Piece Push Back, 2in Male - 1.25in Female Reducer, 2in Male - SCT Male Adapter |
|
|
|
|