Product Name: Specular Reflection Standard, Low Reflectivity
Product Description
The STAN-SSH High-reflectivity Specular Reflectance Standard is a mirrored,
fused-silica standard that can be used as a reference when measuring surfaces
with high specular reflectance values such as optical substrates, optical
coatings, machined metals and semiconductor materials. The STAN-SSH provides an
~85-90% reflectance across the 200-800 nm wavelength range and an ~85-98%
reflectance across the 800-2500 nm range.
The STAN-SSH is available in two versions. The STAN-SSH is $499, and the NIST-traceable
STAN-SSH-NIST is $999.
STAN-SSL Low-reflectivity Specular Reflectance Standard
The STAN-SSL Low-reflectivity Specular Reflectance Standard is a black glass
standard that can be used as a reference when measuring surfaces with low
specular reflectance values such as thin film coatings, anti-reflective
coatings, blocking filters and substrates. The coated surface of the STAN-SSL
provides an ~4.0% reflectance across the 200-2500 nm wavelength range.
The STAN-SSL is available for $499.
The STAN-SSL substrate measures 1.25" in diameter and is housed in a sturdy 1.5"
x 0.75" blue anodized aluminum enclosure and protected by a screw-on top.
User's Tips
- With an Ocean Optics spectrometer, the use of the STAN-SSL is limited to
200-1100 nm.
- Use the STAN-SSL to set a low-reflectivity reference of ~4%.
- Although the black glass is a durable substrate, the user should handle it
with care to maintain the integrity of its calibrated surface.
- To clean the STAN-SSL surface, first remove dirt and dust by blowing it
off with a pressurized gas. Then use the drag method of cleaning to remove
fingerprints and residual contaminants. In the drag method, lens tissue
saturated with reagent-grade isopropyl alcohol or acetone is slowly dragged
across the surface. Done correctly, the solvent will evaporate uniformly with
no streaking or spotting.
STAN-HOLDER Reflectance Standard Holder
The STAN-HOLDER is a convenient accessory option for keeping the standard in
place during measurements. STAN-HOLDER is available for $75.
STAN-SSH Specular Reflectance
See Picture
Specifications
|
Substrate Dimensions: |
1.25" outer diameter x 0.25" height |
|
Housing Dimensions: |
1.5" outer diameter x 0.75" height |
|
Reflectance material: |
Black glass |
|
Reflectivity: |
- ~5.4% (200-950 nm)
- ~4.0% (950-2500 nm)
|
Company Details
Ocean Optics is a leading supplier of solutions for optical sensing – fundamental methods of measuring and interpreting the interaction of light with matter. We enable diverse applications in medical and biological research, environmental... more
| More Products of this Company: |
74-series Lens Fixtures, 84-series Lens Fixture, 84-series Lens Fixture, Absorbing Glass Optical Filters, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, Adjustable Collimating Lens Holder, Cell for Capillary Electrophoresis, CFV-series FluoroVettes, Cosine Correctors for Emission Collection, CUV-ALL-UV 4-way Cuvette Holder for 1-cm Cuvettes, CUV-UV Holder for 1-cm Cuvettes, CUV-VAR Variable Pathlength Cuvette Holder, Cuvette Holder for 10-cm Cuvettes, CVD-UV and CVD-VIS Disposable Cuvettes, Diffuse Reflectance Standards, Electronic TTL Shutter, EviDot Semiconductor Nanocrystals, EviTag Water-stable Quantum Dots, FHS-UV In-Line Filter Holder, FHSA-series Filter and Cuvette Holder, FIA-SIA-LOV Sequential Injection Analysis System, Fiber Optic Scanning Monochromator, Fiber Optic Variable Attenuator, Flow Cell Kit for Flow Injection Analysis, Flow Cell Kit for Flow Injection Analysis, Fluorescence Flow Cell, Fluorescence Flow Cell, Fluorescence Flow Injection Analysis System, Fluorescence Standard, FOIS-1 Fiber Optic Integrating Sphere, FOS-2x2-TTL Inline Fiber Optic Shutter, Gershun Tube Kit, ISP-I Integrating Spheres, ISP-R Integrating Spheres for Reflectance, ISP-REF Integrating Sphere, ISS-2 Integrated Sampling System, ISS-UV-VIS Integrated Sampling System, Longpass Flow Cell, LTP-V Long Trace Profilometer, MPM-2000 Optical Multiplexer, Optical Post Mounts, Posts and Assemblies, Positive Displacement Pump, Power Supply & Controller for LEDs, Precision Optical Flats, Quartz Cells, Reflection and Transmission Stage, Right-angle Collimating Lens Holder, Right-angle Collimating Lens Holder, Shear-plate Collimation Testers, Single-point Reflection Stage, SpectroPipetter for Microliter-volume Samples, Specular Reflection Standards, High Reflectivity, Temperature-regulated Cuvette Holder and Kits, Thin Film Reference Wafer, Variable-angle Reflection Sampling System, Wireless-G Cable Gateway Cable Modem with Built-In Wireless-G Router, Wireless-N Broadband Router: Start a Wireless Network With Up To 4X the Range and 12X the Speed!, Wireless-N Gigabit Gaming Router: Build a high-speed wireless network optimized for gaming!, Wireless-N Gigabit Router with Storage Link: Start a Wireless Network With Up To 4X the Range and 12X the Speed!, Wireless-N Home Router: Start a Wireless Network With Up To 3X the Range and 9X the Speed! |
| Related Products: |
74-series Lens Fixtures, 84-series Lens Fixture, 84-series Lens Fixture, Absorbing Glass Optical Filters, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, Adjustable Collimating Lens Holder, Broadband 200-1100 nm, CG-series Spectrometers, Cell for Capillary Electrophoresis, CFV-series FluoroVettes, CHEM4-UV-FIBER Spectrophotometer, CHEM4-UV-FIBER Spectrophotometer, CHEM4-UV-VIS Spectrophotometer, CHEM4-VIS-FIBER Spectrophotometer, CHEM4-VIS-FIBER Spectrophotometer, CHEM4-VIS-NIR Spectrophotometer, CHEMUSB4-UV-VIS Spectrophotometer, CHEMUSB4-VIS-NIR Spectrophotometer, Cosine Correctors for Emission Collection, CUV-ALL-UV 4-way Cuvette Holder for 1-cm Cuvettes, CUV-UV Holder for 1-cm Cuvettes, CUV-VAR Variable Pathlength Cuvette Holder, Cuvette Holder for 10-cm Cuvettes, CVD-UV and CVD-VIS Disposable Cuvettes, Diffuse Reflectance Standards |
| Suitable For: |
light - spectrometer - spectrometers - Ocean Optics - sampling accessories - collimating lens - cuvette holder - cuvette - sampling systems for fluid analysis - fluorescence sampling tools - light collection tools - light measurement - flow cells - fluorovette - positive displacement pump - optical post mounts - reflection measurement tools - metrology - filter holder - mapping table - integrating sphere - reflectance standard - nanopositiioner - specular reflectance - absorbance standard - NIST - Raman standard - probe - cosine correction - radiometric standard -
|
|
|
|