Product Name: Diffuse Reflectance Standards
Product Description
WS-1 Diffuse Reflection Standard
The WS-1 Diffuse Reflectance Standard is made of PTFE, a diffuse white
plastic that provides a Lambertian reference surface for reflectance
experiments. The WS-1 comes in an anodized aluminum housing, and is hydrophobic,
chemically inert and very stable, even in deep-ultraviolet applications. It is
>98% reflective from 250-1500 nm and >95% reflective from 250-2200 nm.
The reflective area of the WS-1 has a 32 mm OD. The diffusing material is
encased in a small receptacle with screw-on top. The material is almost
uniformly reflective (>95%) by wavelength across the entire range of 250-2000
nm.
WS-1: $299.
WS-1-SL White Reflection Standard with Spectralon
The WS-1-SL is a diffuse reflectance standard from Labsphere and is made from
their patented diffuse reflectance material, Spectralon. Spectralon is
hydrophobic and is thermally stable to 350 °C. The durable material provides
highly accurate, reproducible data. Unlike all the other PTFE-based standards on
this page, the WS-1-SL often can be smoothed, flattened and cleaned if nicked or
soiled.
WS-1-SL: $329
WS-1-SS White Standard with Stainless-steel Housing
The WS-1-SS comes in a stainless steel housing and has the same properties as
the WS-1. In addition, the surface of the WS-1-SS is slightly recessed to allow
the RPH-1 Reflection Probe Holder to sit on the standard without coming in
direct contact with the standard’s surface. WS-1-SS: $364
WS-1-SS: $408
WS-1-GEM White Standard
Conceived for use in colorimetric applications involving diamonds and other
gems, the WS-3-GEM White Reference Tile consists of a diffuse PTFE-based
material, shaped to form a holder within its stainless steel receptacle. Because
of its concave shape, the WS-3-GEM becomes an integrating sphere when
illuminated.
The WS-3-GEM has >98% reflectivity from 400-1500 nm and >95% reflectivity from
250-2000 nm. Like the WS-1, the WS-3-GEM's reflectance material is hydrophobic,
chemically inert and very stable, even in deep-UV applications.
WS-3-GEM: $546
Specifications
|
Specification |
WS-1 |
WS-1-SL |
WS-1-SS |
WS-3-GEM |
| Dimensions housing: |
38 mm diameter |
38 mm diameter |
38 mm diameter |
38 mm diameter |
| Dimensions tile: |
32 mm OD,
10 mm thick |
32 mm OD,
10 mm thick |
32 mm OD,
10 mm thick |
31 mm OD,
10 mm thick |
| Weight: |
30 g |
30 g |
30 g |
70 g |
| Spectral range: |
250-2000 nm |
250-2500 nm |
250-2000 nm |
250-2000 nm |
| Housing: |
Aluminum |
Delrin holder, protective cover |
Stainless steel |
Stainless steel |
| Reflectivity: |
>98% (250-1500 nm)
>95% (250-2200 nm) |
99% (400-1500 nm)
>96% (250-2000 nm) |
>98% (250-1500 nm)
>95% (250-2200 nm) |
>98% (250-1500 nm)
>95% (250-2200 nm) |
Company Details
Ocean Optics is a leading supplier of solutions for optical sensing – fundamental methods of measuring and interpreting the interaction of light with matter. We enable diverse applications in medical and biological research, environmental... more
| More Products of this Company: |
74-series Lens Fixtures, 84-series Lens Fixture, 84-series Lens Fixture, Absorbing Glass Optical Filters, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, Adjustable Collimating Lens Holder, Cell for Capillary Electrophoresis, CFV-series FluoroVettes, Cosine Correctors for Emission Collection, CUV-ALL-UV 4-way Cuvette Holder for 1-cm Cuvettes, CUV-UV Holder for 1-cm Cuvettes, CUV-VAR Variable Pathlength Cuvette Holder, Cuvette Holder for 10-cm Cuvettes, CVD-UV and CVD-VIS Disposable Cuvettes, Electronic TTL Shutter, EviDot Semiconductor Nanocrystals, EviTag Water-stable Quantum Dots, FHS-UV In-Line Filter Holder, FHSA-series Filter and Cuvette Holder, FIA-SIA-LOV Sequential Injection Analysis System, Fiber Optic Scanning Monochromator, Fiber Optic Variable Attenuator, Flow Cell Kit for Flow Injection Analysis, Flow Cell Kit for Flow Injection Analysis, Fluorescence Flow Cell, Fluorescence Flow Cell, Fluorescence Flow Injection Analysis System, Fluorescence Standard, FOIS-1 Fiber Optic Integrating Sphere, FOS-2x2-TTL Inline Fiber Optic Shutter, Gershun Tube Kit, ISP-I Integrating Spheres, ISP-R Integrating Spheres for Reflectance, ISP-REF Integrating Sphere, ISS-2 Integrated Sampling System, ISS-UV-VIS Integrated Sampling System, Longpass Flow Cell, LTP-V Long Trace Profilometer, MPM-2000 Optical Multiplexer, Optical Post Mounts, Posts and Assemblies, Positive Displacement Pump, Power Supply & Controller for LEDs, Precision Optical Flats, Quartz Cells, Reflection and Transmission Stage, Right-angle Collimating Lens Holder, Right-angle Collimating Lens Holder, Shear-plate Collimation Testers, Single-point Reflection Stage, SpectroPipetter for Microliter-volume Samples, Specular Reflection Standard, Low Reflectivity, Specular Reflection Standards, High Reflectivity, Temperature-regulated Cuvette Holder and Kits, Thin Film Reference Wafer, Variable-angle Reflection Sampling System, Wireless-G Cable Gateway Cable Modem with Built-In Wireless-G Router, Wireless-N Broadband Router: Start a Wireless Network With Up To 4X the Range and 12X the Speed!, Wireless-N Gigabit Gaming Router: Build a high-speed wireless network optimized for gaming!, Wireless-N Gigabit Router with Storage Link: Start a Wireless Network With Up To 4X the Range and 12X the Speed!, Wireless-N Home Router: Start a Wireless Network With Up To 3X the Range and 9X the Speed! |
| Related Products: |
74-series Lens Fixtures, 84-series Lens Fixture, 84-series Lens Fixture, Absorbing Glass Optical Filters, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, Adjustable Collimating Lens Holder, Cell for Capillary Electrophoresis, CFV-series FluoroVettes, CHEM4-UV-FIBER Spectrophotometer, CHEM4-UV-FIBER Spectrophotometer, CHEM4-VIS-FIBER Spectrophotometer, CHEM4-VIS-FIBER Spectrophotometer, Cosine Correctors for Emission Collection, CUV-ALL-UV 4-way Cuvette Holder for 1-cm Cuvettes, CUV-UV Holder for 1-cm Cuvettes, CUV-VAR Variable Pathlength Cuvette Holder, Cuvette Holder for 10-cm Cuvettes, CVD-UV and CVD-VIS Disposable Cuvettes, Electronic TTL Shutter, EviDot Semiconductor Nanocrystals, EviTag Water-stable Quantum Dots, FHS-UV In-Line Filter Holder, FHSA-series Filter and Cuvette Holder, FIA-SIA-LOV Sequential Injection Analysis System |
| Suitable For: |
light - spectrometer - spectrometers - Ocean Optics - sampling accessories - collimating lens - cuvette holder - cuvette - sampling systems for fluid analysis - fluorescence sampling tools - light collection tools - light measurement - flow cells - fluorovette - positive displacement pump - optical post mounts - reflection measurement tools - metrology - filter holder - mapping table - integrating sphere - reflectance standard - nanopositiioner - specular reflectance - absorbance standard - NIST - Raman standard - probe - cosine correction - radiometric standard -
|
|
|
|