Product Name: Fiber Optic Scanning Monochromator

Product Description

Fiber Optic Scanning Monochromator
Monochromator Allows 2 nm Bandwidth

The MonoScan2000 is a computer-controlled scanning monochromator with a 300-700 nm wavelength range. It takes the MonoScan2000 only three seconds to scan from 300-700 nm. To scan only one nanometer takes about 15-20 milliseconds. The MonoScan2000 is compatible with all Ocean Optics spectrometers, light sources, accessories and optical fibers.

Use as a Tunable Light Source or Excitation for Fluorescence

In this setup, a broadband light source provides light via optical fiber to the MonoScan2000. You select a 2-to-3 nm bandpass in which the light passes before exiting the MonoScan, interacting with a sample and passing to a spectrometer. In this situation, the MonoScan takes the place of a filter. A scanning monochromator is better able to provide excitation intensity than a filter because of the monochromator’s ability to reject out-of-band illumination. Filters can provide adequate excitation intensity but at reduced optical transmittance because they typically have a wider bandpass. You often sacrifice dynamic range with filters.

Use with Single-element Detector

A light source provides light via optical fiber to a sample, interacts with the sample, and sends light to the MonoScan2000. The monochromator captures the incoming light, transmits it via fiber to a single-element detector, such as a photodiode, one wavelength at a time. The MonoScan2000 allows a high optical throughput and provides an intense spectral signal. The MonoScan has the ability to scan through a wavelength range you select via software. Because the MonoScan has no slit, the diameter size of the optical fiber determines the optical resolution of the system. When using 200 µm fibers, for example, optical resolution is <3 nm (FWHM).

The MonoScan2000 is available for $5373.

Specifications

Dimensions: 112 mm x 132 mm x 145 mm
Weight: 1.1 kg
Wavelength range: 300-700 nm
Optical resolution: Depends on the diameter of the optical fiber; ~4 nm (FWHM) using a 400 µm diameter optical fiber
Holographic grating: 1250 lines/mm, blazed at 350 nm
Accuracy: <0.5 nm
Repeatability: 0.2 nm
Transition speed: From scan from 300 nm to 700 nm takes ~3 seconds
A one nanometer step takes ~15-20 milliseconds
Dispersion: ~10 nm per mm
Optical throughput: >50% with a 1000 µm fiber at 350 nm
                              >30% with a 1000 µm fiber at 500 nm
Grating scan angle: 14.8° (300-700 nm)
Computer interface: USB and RS-232
Power requirement: 12 VDC max. 1.2A (WT-12V-E)
Gearbox ratio: 1:261

Fiber Optic Scanning Monochromator

Company Details

Ocean Optics is a leading supplier of solutions for optical sensing – fundamental methods of measuring and interpreting the interaction of light with matter. We enable diverse applications in medical and biological research, environmental... more

More Products of this Company: 74-series Lens Fixtures, 84-series Lens Fixture, 84-series Lens Fixture, Absorbing Glass Optical Filters, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, Adjustable Collimating Lens Holder, Cell for Capillary Electrophoresis, CFV-series FluoroVettes, Cosine Correctors for Emission Collection, CUV-ALL-UV 4-way Cuvette Holder for 1-cm Cuvettes, CUV-UV Holder for 1-cm Cuvettes, CUV-VAR Variable Pathlength Cuvette Holder, Cuvette Holder for 10-cm Cuvettes, CVD-UV and CVD-VIS Disposable Cuvettes, Diffuse Reflectance Standards, Electronic TTL Shutter, EviDot Semiconductor Nanocrystals, EviTag Water-stable Quantum Dots, FHS-UV In-Line Filter Holder, FHSA-series Filter and Cuvette Holder, FIA-SIA-LOV Sequential Injection Analysis System, Fiber Optic Variable Attenuator, Flow Cell Kit for Flow Injection Analysis, Flow Cell Kit for Flow Injection Analysis, Fluorescence Flow Cell, Fluorescence Flow Cell, Fluorescence Flow Injection Analysis System, Fluorescence Standard, FOIS-1 Fiber Optic Integrating Sphere, FOS-2x2-TTL Inline Fiber Optic Shutter, Gershun Tube Kit, ISP-I Integrating Spheres, ISP-R Integrating Spheres for Reflectance, ISP-REF Integrating Sphere, ISS-2 Integrated Sampling System, ISS-UV-VIS Integrated Sampling System, Longpass Flow Cell, LTP-V Long Trace Profilometer, MPM-2000 Optical Multiplexer, Optical Post Mounts, Posts and Assemblies, Positive Displacement Pump, Power Supply & Controller for LEDs, Precision Optical Flats, Quartz Cells, Reflection and Transmission Stage, Right-angle Collimating Lens Holder, Right-angle Collimating Lens Holder, Shear-plate Collimation Testers, Single-point Reflection Stage, SpectroPipetter for Microliter-volume Samples, Specular Reflection Standard, Low Reflectivity, Specular Reflection Standards, High Reflectivity, Temperature-regulated Cuvette Holder and Kits, Thin Film Reference Wafer, Variable-angle Reflection Sampling System, Wireless-G Cable Gateway Cable Modem with Built-In Wireless-G Router, Wireless-N Broadband Router: Start a Wireless Network With Up To 4X the Range and 12X the Speed!, Wireless-N Gigabit Gaming Router: Build a high-speed wireless network optimized for gaming!, Wireless-N Gigabit Router with Storage Link: Start a Wireless Network With Up To 4X the Range and 12X the Speed!, Wireless-N Home Router: Start a Wireless Network With Up To 3X the Range and 9X the Speed!
Related Products: 74-series Lens Fixtures, 84-series Lens Fixture, 84-series Lens Fixture, Broadband 200-1100 nm, CG-series Spectrometers, CHEM4-UV-FIBER Spectrophotometer, CHEM4-UV-FIBER Spectrophotometer, CHEM4-UV-VIS Spectrophotometer, CHEM4-VIS-FIBER Spectrophotometer, CHEM4-VIS-FIBER Spectrophotometer, CHEM4-VIS-NIR Spectrophotometer, CHEMUSB4-UV-VIS Spectrophotometer, CHEMUSB4-VIS-NIR Spectrophotometer, Cosine Correctors for Emission Collection, CUV-ALL-UV 4-way Cuvette Holder for 1-cm Cuvettes, CUV-UV Holder for 1-cm Cuvettes, CUV-VAR Variable Pathlength Cuvette Holder, Cuvette Holder for 10-cm Cuvettes, DTS-series MEMS-based NIR Spectrometers, FHS-UV In-Line Filter Holder, FIA-SIA-LOV Sequential Injection Analysis System, Fiber Optic pH Sensors, Fiber Optic Variable Attenuator, Flow Cell Kit for Flow Injection Analysis, Flow Cell Kit for Flow Injection Analysis, Fluorescence Flow Cell
Suitable For: light - spectrometer - spectrometers - Ocean Optics - sampling accessories - collimating lens - cuvette holder - cuvette - sampling systems for fluid analysis - fluorescence sampling tools - light collection tools - light measurement - flow cells - fluorovette - positive displacement pump - optical post mounts - reflection measurement tools - metrology - filter holder - mapping table - integrating sphere - reflectance standard - nanopositiioner - specular reflectance - absorbance standard - NIST - Raman standard - probe - cosine correction - radiometric standard -
Home | Members.Benefit | Privacy.Policy | Bookmark.This.Page | Contact.Us
© 2006 - 2007 4engr. All Rights reserved

|Conveyor technology