Login:   Password:
Not Register?    Sign Up NOW!
Date: 21 November 2009
Google
 
Fluorescence Flow Injection Analysis System  
Search Country Category Type   Reset filter

Fluorescence Flow Injection Analysis System
United States
United States

Product Name: Fluorescence Flow Injection Analysis System

Product Description

The FIA-PMT-FL is a highly sensitive -- to parts per trillion -- photomultiplier-based flow through detection system ideally suited for ultra-low fluorescence, chemiluminescence or bioluminescence measurements. The system's heavy-duty, chemically resistant housing is built to withstand industrial environments.

The FIA-PMT-FL has flow-through capability, but also accepts standard 1-cm path length cuvettes for manual measurements. The FIA-PMT-FL is $6,495.

System Configuration

The FIA-PMT is built to order with either an internal excitation lamp or with an optical fiber interfacing to an external lamp. Excitation lamp source options include tungsten, mercury vapor, LEDs and laser diodes. Emission and excitation filters are mounted in accessible slots inside the enclosure, allowing for easy removal or exchange. The system uses an internal 25 mm flow cell.

Excitation Source Options

Internal excitation source options: Laser diodes (532 nm, 635 nm, 650 nm)
Quartz tungsten lamp (440-750 nm)
UV LED lamp (365-410 nm)
Various Visible LED lamps
Fiber optic excitation source options: Deuterium lamp (200-400 nm)
Laser diodes (532 nm, 635 nm, 650 nm)
Quartz tungsten lamp (440-750 nm)

System Operation

The FIA-PMT-FL plugs into the RS-232 serial port of a personal computer and comes with Windows-based software that allows the user to set the integration time and voltage counts, and to obtain time histories of the measurements, both plotted and tabulated. Also, the software can automatically create calibration curves, and control a host of additional devices including various syringe and peristaltic pumps, injection valves, selection valves, and autosamplers (please inquire for details). For users who desire to control the PMT-FL from their own software project, included is an ActiveX control for use with Visual Basic, VC++, LabvVew, or nearly any other ActiveX- compatible development environment.

Typical Applications

Fluorometric ammonium analysis. Use the FIA-PMT-FL for the orthophtaldialdehyde (OPA) method for NH4 assays, to ppb sensitivity. Results achieved with 365 nm LED excitation source with broadband 410-490 nm emission filter.

Fluorescein-based assays. Use the FIA-PMT-FL to measure to ppb sensitivity. Results achieved with Blue LED excitation source and broadband 510-590 nm emission filter.

Additional Options

  • Heated internal flow cell -- ambient to 60 °C, +/- 0.5 °C accuracy
  • Dual-head PMT -- measure two excitation wavelength bands simultaneously

Specifications

Dimensions: ~13 cm x 18 cm x 25.4 cm
Spectral range: 310-750 nm (filter/lamp selection dependent)
Detector: Photo-counting photomultiplier tube
PMT dynamic range: 2 x 10^6
Responsivity: 5 x 10^17 cps/watt (@ 400 nm)
Detection limits: 10 parts per trillion measured with fluorescein @ 200 msec integration time and internal LED
Pulse-pair resolution: 10 ns
Flow cell: 10 mm path, 25 µL volume with flow-through cuvette
Filters: Your waveband choice of 1 excitation filter and 1 emission filter (call for options)
Computer interface: RS-232 to Windows 98/Me/2000/XP OS


Company Details

Ocean Optics is a leading supplier of solutions for optical sensing – fundamental methods of measuring and interpreting the interaction of light with matter. We enable diverse applications in medical and biological research, environmental... more

More Products of this Company: 74-series Lens Fixtures, 84-series Lens Fixture, 84-series Lens Fixture, Absorbing Glass Optical Filters, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, Adjustable Collimating Lens Holder, Cell for Capillary Electrophoresis, CFV-series FluoroVettes, Cosine Correctors for Emission Collection, CUV-ALL-UV 4-way Cuvette Holder for 1-cm Cuvettes, CUV-UV Holder for 1-cm Cuvettes, CUV-VAR Variable Pathlength Cuvette Holder, Cuvette Holder for 10-cm Cuvettes, CVD-UV and CVD-VIS Disposable Cuvettes, Diffuse Reflectance Standards, Electronic TTL Shutter, EviDot Semiconductor Nanocrystals, EviTag Water-stable Quantum Dots, FHS-UV In-Line Filter Holder, FHSA-series Filter and Cuvette Holder, FIA-SIA-LOV Sequential Injection Analysis System, Fiber Optic Scanning Monochromator, Fiber Optic Variable Attenuator, Flow Cell Kit for Flow Injection Analysis, Flow Cell Kit for Flow Injection Analysis, Fluorescence Flow Cell, Fluorescence Flow Cell, Fluorescence Standard, FOIS-1 Fiber Optic Integrating Sphere, FOS-2x2-TTL Inline Fiber Optic Shutter, Gershun Tube Kit, ISP-I Integrating Spheres, ISP-R Integrating Spheres for Reflectance, ISP-REF Integrating Sphere, ISS-2 Integrated Sampling System, ISS-UV-VIS Integrated Sampling System, Longpass Flow Cell, LTP-V Long Trace Profilometer, MPM-2000 Optical Multiplexer, Optical Post Mounts, Posts and Assemblies, Positive Displacement Pump, Power Supply & Controller for LEDs, Precision Optical Flats, Quartz Cells, Reflection and Transmission Stage, Right-angle Collimating Lens Holder, Right-angle Collimating Lens Holder, Shear-plate Collimation Testers, Single-point Reflection Stage, SpectroPipetter for Microliter-volume Samples, Specular Reflection Standard, Low Reflectivity, Specular Reflection Standards, High Reflectivity, Temperature-regulated Cuvette Holder and Kits, Thin Film Reference Wafer, Variable-angle Reflection Sampling System, Wireless-G Cable Gateway Cable Modem with Built-In Wireless-G Router, Wireless-N Broadband Router: Start a Wireless Network With Up To 4X the Range and 12X the Speed!, Wireless-N Gigabit Gaming Router: Build a high-speed wireless network optimized for gaming!, Wireless-N Gigabit Router with Storage Link: Start a Wireless Network With Up To 4X the Range and 12X the Speed!, Wireless-N Home Router: Start a Wireless Network With Up To 3X the Range and 9X the Speed!
Related Products: 74-series Lens Fixtures, 84-series Lens Fixture, 84-series Lens Fixture, Absorbing Glass Optical Filters, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, Adjustable Collimating Lens Holder, Broadband 200-1100 nm, CG-series Spectrometers, Cell for Capillary Electrophoresis, CFV-series FluoroVettes, CHEM4-UV-FIBER Spectrophotometer, CHEM4-UV-FIBER Spectrophotometer, CHEM4-UV-VIS Spectrophotometer, CHEM4-VIS-FIBER Spectrophotometer, CHEM4-VIS-FIBER Spectrophotometer, CHEM4-VIS-NIR Spectrophotometer, CHEMUSB4-UV-VIS Spectrophotometer, CHEMUSB4-VIS-NIR Spectrophotometer, Cosine Correctors for Emission Collection, CUV-ALL-UV 4-way Cuvette Holder for 1-cm Cuvettes, CUV-UV Holder for 1-cm Cuvettes, CUV-VAR Variable Pathlength Cuvette Holder, Cuvette Holder for 10-cm Cuvettes, CVD-UV and CVD-VIS Disposable Cuvettes, Diffuse Reflectance Standards
Suitable For: light - spectrometer - spectrometers - Ocean Optics - sampling accessories - collimating lens - cuvette holder - cuvette - sampling systems for fluid analysis - fluorescence sampling tools - light collection tools - light measurement - flow cells - fluorovette - positive displacement pump - optical post mounts - reflection measurement tools - metrology - filter holder - mapping table - integrating sphere - reflectance standard - nanopositiioner - specular reflectance - absorbance standard - NIST - Raman standard - probe - cosine correction - radiometric standard -
Home | Members.Benefit | Privacy.Policy | Bookmark.This.Page | Contact.Us
© 2006 - 2007 4engr. All Rights reserved

|Conveyor technology