Cell for Capillary Electrophoresis  
Search Country Category Type   Reset filter

Cell for Capillary Electrophoresis
United States
United States

Product Name: Cell for Capillary Electrophoresis

Product Description

The CUV-CCE Chromatography and Capillary Electrophoresis Sample Cell is an optical fixture for measuring relative absorbance of fluids in chromatography or capillary electrophoresis systems. The cell is attached on-line, i.e., the light is projected through the sides of fused silica tubing without violating the tube integrity. For this reason, there are no pressure limitations associated with the device.

The CUV-CCE Chromatography and Capillary Electrophoresis Sample Cell features the following key benefits:

  • Measures UV absorbance of fluids in electrophoresis systems
  • No pressure limitations
  • Sample cell comes with two solarization-resistant fibers
  • PEEK material of the fixtures and fittings boasts excellent chemical resistance

The CUV-CCE can accommodate fused silica tubing up to 500 mm in diameter. The CUV-CCE comes with Upchurch F230 0.015" ID tubing sleeves. However, different inner-diameter tubing sleeves are available to fit various tubing sizes.

The cell fixture is made from a standard 10-32 PEEK Cross (Upchurch # P-729) with a 0.020" through-hole, 10-32 coned female threads and (4) F-300 PEEK fingertight fittings. Two 300-mm diameter, solarization-resistant optical fibers are included with the CUV-CCE. The optical fibers are aluminum-jacketed, silica-core/silica-clad UV waveguides. The optical fibers are inserted facing each other across the sample tubing, and secured with the same F230 0.015" ID tubing sleeves and fingertight fittings.

The CUV-CCE is available for only $599.

The user must provide a clear optical window by eliminating the jacketing of the tubing. This is easily accomplished by burning off the section of the jacketing that will be positioned in the cross.

User's Tip

To use the CUV-CCE, we recommend a spectrometer unit with an L2 Detector Collection Lens, either Grating #1 or #2, a 25 mm slit, the UV2 UV Detector Upgrade and an OFLV-200-850 Order-sorting Filter.

Specifications

Dimensions (mm): 28.6 x 28.6 (cross); 50.8 x 50.8 (cross with fittings)
Weight: 9.4 g
Material: PEEK polymer
Threads: 10-32
Through-hole size (mm): 0.51
Fittings: (4) F-300 double-winged nuts with F-142 ferrules
Tubing size accommodated: 350-390  µm OD
Pressure rating (tubing): 6,000 psi (414 bar)
Tube sleeve dimensions (mm): 0.41 inner diameter, 31.8 length
UV waveguide optical fibers:
  • Al-jacketed
  • 300-mm diameter
  • Solarization-resistant
  • Silica-core/silica-clad
Path length: Silica tubing diameter


Company Details

Ocean Optics is a leading supplier of solutions for optical sensing – fundamental methods of measuring and interpreting the interaction of light with matter. We enable diverse applications in medical and biological research, environmental... more

More Products of this Company: 74-series Lens Fixtures, 84-series Lens Fixture, 84-series Lens Fixture, Absorbing Glass Optical Filters, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, Adjustable Collimating Lens Holder, CFV-series FluoroVettes, Cosine Correctors for Emission Collection, CUV-ALL-UV 4-way Cuvette Holder for 1-cm Cuvettes, CUV-UV Holder for 1-cm Cuvettes, CUV-VAR Variable Pathlength Cuvette Holder, Cuvette Holder for 10-cm Cuvettes, CVD-UV and CVD-VIS Disposable Cuvettes, Diffuse Reflectance Standards, Electronic TTL Shutter, EviDot Semiconductor Nanocrystals, EviTag Water-stable Quantum Dots, FHS-UV In-Line Filter Holder, FHSA-series Filter and Cuvette Holder, FIA-SIA-LOV Sequential Injection Analysis System, Fiber Optic Scanning Monochromator, Fiber Optic Variable Attenuator, Flow Cell Kit for Flow Injection Analysis, Flow Cell Kit for Flow Injection Analysis, Fluorescence Flow Cell, Fluorescence Flow Cell, Fluorescence Flow Injection Analysis System, Fluorescence Standard, FOIS-1 Fiber Optic Integrating Sphere, FOS-2x2-TTL Inline Fiber Optic Shutter, Gershun Tube Kit, ISP-I Integrating Spheres, ISP-R Integrating Spheres for Reflectance, ISP-REF Integrating Sphere, ISS-2 Integrated Sampling System, ISS-UV-VIS Integrated Sampling System, Longpass Flow Cell, LTP-V Long Trace Profilometer, MPM-2000 Optical Multiplexer, Optical Post Mounts, Posts and Assemblies, Positive Displacement Pump, Power Supply & Controller for LEDs, Precision Optical Flats, Quartz Cells, Reflection and Transmission Stage, Right-angle Collimating Lens Holder, Right-angle Collimating Lens Holder, Shear-plate Collimation Testers, Single-point Reflection Stage, SpectroPipetter for Microliter-volume Samples, Specular Reflection Standard, Low Reflectivity, Specular Reflection Standards, High Reflectivity, Temperature-regulated Cuvette Holder and Kits, Thin Film Reference Wafer, Variable-angle Reflection Sampling System, Wireless-G Cable Gateway Cable Modem with Built-In Wireless-G Router, Wireless-N Broadband Router: Start a Wireless Network With Up To 4X the Range and 12X the Speed!, Wireless-N Gigabit Gaming Router: Build a high-speed wireless network optimized for gaming!, Wireless-N Gigabit Router with Storage Link: Start a Wireless Network With Up To 4X the Range and 12X the Speed!, Wireless-N Home Router: Start a Wireless Network With Up To 3X the Range and 9X the Speed!
Related Products: CUV-UV Holder for 1-cm Cuvettes, CUV-VAR Variable Pathlength Cuvette Holder, Cuvette Holder for 10-cm Cuvettes, EviTag Water-stable Quantum Dots, FIA-SIA-LOV Sequential Injection Analysis System, Fiber Optic pH Sensors, Flow Cell Kit for Flow Injection Analysis, Flow Cell Kit for Flow Injection Analysis, Fluorescence Flow Cell, Fluorescence Flow Cell, Fluorescence Flow Injection Analysis System, HR2000+ High-resolution Spectrometer, HR4000 High-resolution Spectrometer, HR4000CG-UV-NIR Broadband Spectrometer, Hydrorad Environmental Radiometer, LIBS Broadband Spectrometer System, LIBS-ELITE Spectrometer System, Longpass Flow Cell, NanoCalc Thin Film Reflectometry System, NIR-512 Near-infrared Spectrometer, NIR256-2.1 NIR Spectrometer and NIR256-2.5 Extended-range NIR Spectrometer, OOISensors Software for Oxygen Measurements, Oxygen Sensor, Phenol Red pH Test Kit, PlasCalc Plasma Monitoring System
Suitable For: light - spectrometer - spectrometers - Ocean Optics - sampling accessories - collimating lens - cuvette holder - cuvette - sampling systems for fluid analysis - fluorescence sampling tools - light collection tools - light measurement - flow cells - fluorovette - positive displacement pump - optical post mounts - reflection measurement tools - metrology - filter holder - mapping table - integrating sphere - reflectance standard - nanopositiioner - specular reflectance - absorbance standard - NIST - Raman standard - probe - cosine correction - radiometric standard -
Home | Members.Benefit | Privacy.Policy | Bookmark.This.Page | Contact.Us
© 2006 - 2007 4engr. All Rights reserved

|Conveyor technology