Product Name: Flow Cell Kit for Flow Injection Analysis
Product Description
The FIA-1000-Z Flow Cell Kit is a convenient, low-cost fluid handling
system that couples to Ocean Optics high-sensitivity miniature fiber optic
spectrometers and light sources for rapid, quantitative analysis of solutions.
The FIA-1000-Z system consists of a two-channel peristaltic pump, a 1-cm path
length fiber optic flow cell, a fittings kit and Windows-based operating
software. A pair of optical fibers or special bifurcated assembly (priced
separately) completes the package.
In the Z-SMA flow cell setup (item FIA-1000-Z), the peristaltic pump delivers
precise volumes of solutions for continuous or stopped-flow spectroscopic
readings. In addition, the pump can be operated manually or with a desktop or
notebook PC, in either the continuous-flow or stopped-flow modes.
The Z-SMA flow cell has an optical path length of 10 mm, an inner diameter of
1.5 mm, and is available in high-grade stainless steel, PEEK, PlexiglasÒ or
Teflon.
The cell features fused-silica windows that allow for signal transmission from
~170 nm - 2 mm (with an Ocean Optics spectrometer, the practical use of the cell
is limited to 200-1100 nm).
The Z-SMA setup uses standard SMA-terminated optical fibers -- a pair of either
200 mm or 400 mm -- that connect to an Ocean Optics USB2000 Miniature Fiber
Optic Spectrometer and light source to create a fully integrated analytical
instrument. Also available is an adjustable Z cell, which uses a pair of
specially terminated optical fibers.
FIA-1000-Z Fluid Sampling Systems -- Specifications
|
Spectral range: |
260-2000 nm |
|
Cell materials: |
PEEK, Plexiglas, Teflon or Stainless steel |
|
Inner diameter: |
1.5 mm |
|
Window material: |
UV-grade fused silica |
|
Pathlength: |
10 mm |
|
Fiber connectors: |
SMA 905 |
|
Tubing: |
1/16" Teflon, ~3m |
|
Tubing connectors: |
1/4-28 |
|
Pump dimensions: |
105 mm x 105 mm x 185 mm |
|
Pump weight: |
2100 g |
|
Flow rate: |
200 mL/minute/channel (depending on RPM and tubing diameter) |
|
Pressure rating: |
25 psi |
FIA-1000 Fluid Sampling Systems -- Components and Pricing
|
Item |
Description |
Price |
|
FIA-1000-Z |
Z-SMA flow cell with peristaltic pump. Includes
operating software with code for computer control of pump. User specifies
cell material. Standard cell materials are Teflon and Plexiglas. Stainless
steel and PEEK polymer cell materials are available at $70 extra cost. |
$1,300 |
|
FIA-Z-SMA |
Replacement Z-SMA flow cell for FIA-1000-Z. User
specifies cell material. Standard cell materials are Teflon, Plexiglas,
Stainless steel or PEEK polymer. |
$529 |
|
FIA-Z-CELL |
Adjustable replacement cell for use with
FIA-1000-Z. Connects to fiber optics w/ferrule termination. Standard cell
materials are Plexiglas, Stainless steel or PEEK. |
$365 |
|
FIA-Z-CELL-TEF |
Adjustable replacement cell for use with
FIA-1000-Z. Connects to fiber optics w/ferrule termination. Teflon material. |
$365 |
|
FIA-P200-UV |
Custom 200 µm ferrule-termination fiber optic
for use with FIA-Z-CELL; requires 2 fibers. |
$210 |
|
FIA-P400-UV |
Custom 400 µm ferrule-termination fiber optic
for use with FIA-Z-CELL; requires 2 fibers. |
$215 |
|
FIA-BIF400-UV |
Custom bifurcated 400 µm fiber assembly for use
with FIA-1000-S. |
$435 |
|
FIA-PUMP-C |
Replacement peristaltic pump
(computer-controlled) for FIA-1000 flow cells |
$804 |
Company Details
Ocean Optics is a leading supplier of solutions for optical sensing – fundamental methods of measuring and interpreting the interaction of light with matter. We enable diverse applications in medical and biological research, environmental... more
| More Products of this Company: |
74-series Lens Fixtures, 84-series Lens Fixture, 84-series Lens Fixture, Absorbing Glass Optical Filters, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, Adjustable Collimating Lens Holder, Cell for Capillary Electrophoresis, CFV-series FluoroVettes, Cosine Correctors for Emission Collection, CUV-ALL-UV 4-way Cuvette Holder for 1-cm Cuvettes, CUV-UV Holder for 1-cm Cuvettes, CUV-VAR Variable Pathlength Cuvette Holder, Cuvette Holder for 10-cm Cuvettes, CVD-UV and CVD-VIS Disposable Cuvettes, Diffuse Reflectance Standards, Electronic TTL Shutter, EviDot Semiconductor Nanocrystals, EviTag Water-stable Quantum Dots, FHS-UV In-Line Filter Holder, FHSA-series Filter and Cuvette Holder, FIA-SIA-LOV Sequential Injection Analysis System, Fiber Optic Scanning Monochromator, Fiber Optic Variable Attenuator, Flow Cell Kit for Flow Injection Analysis, Fluorescence Flow Cell, Fluorescence Flow Cell, Fluorescence Flow Injection Analysis System, Fluorescence Standard, FOIS-1 Fiber Optic Integrating Sphere, FOS-2x2-TTL Inline Fiber Optic Shutter, Gershun Tube Kit, ISP-I Integrating Spheres, ISP-R Integrating Spheres for Reflectance, ISP-REF Integrating Sphere, ISS-2 Integrated Sampling System, ISS-UV-VIS Integrated Sampling System, Longpass Flow Cell, LTP-V Long Trace Profilometer, MPM-2000 Optical Multiplexer, Optical Post Mounts, Posts and Assemblies, Positive Displacement Pump, Power Supply & Controller for LEDs, Precision Optical Flats, Quartz Cells, Reflection and Transmission Stage, Right-angle Collimating Lens Holder, Right-angle Collimating Lens Holder, Shear-plate Collimation Testers, Single-point Reflection Stage, SpectroPipetter for Microliter-volume Samples, Specular Reflection Standard, Low Reflectivity, Specular Reflection Standards, High Reflectivity, Temperature-regulated Cuvette Holder and Kits, Thin Film Reference Wafer, Variable-angle Reflection Sampling System, Wireless-G Cable Gateway Cable Modem with Built-In Wireless-G Router, Wireless-N Broadband Router: Start a Wireless Network With Up To 4X the Range and 12X the Speed!, Wireless-N Gigabit Gaming Router: Build a high-speed wireless network optimized for gaming!, Wireless-N Gigabit Router with Storage Link: Start a Wireless Network With Up To 4X the Range and 12X the Speed!, Wireless-N Home Router: Start a Wireless Network With Up To 3X the Range and 9X the Speed! |
| Related Products: |
74-series Lens Fixtures, 84-series Lens Fixture, 84-series Lens Fixture, Absorbing Glass Optical Filters, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, Adjustable Collimating Lens Holder, Cell for Capillary Electrophoresis, CFV-series FluoroVettes, Cosine Correctors for Emission Collection, CUV-ALL-UV 4-way Cuvette Holder for 1-cm Cuvettes, CUV-UV Holder for 1-cm Cuvettes, CUV-VAR Variable Pathlength Cuvette Holder, Cuvette Holder for 10-cm Cuvettes, CVD-UV and CVD-VIS Disposable Cuvettes, Diffuse Reflectance Standards, Electronic TTL Shutter, EviDot Semiconductor Nanocrystals, EviTag Water-stable Quantum Dots, FHS-UV In-Line Filter Holder, FHSA-series Filter and Cuvette Holder, FIA-SIA-LOV Sequential Injection Analysis System, Fiber Optic pH Sensors, Fiber Optic Scanning Monochromator, Fiber Optic Variable Attenuator |
| Suitable For: |
light - spectrometer - spectrometers - Ocean Optics - sampling accessories - collimating lens - cuvette holder - cuvette - sampling systems for fluid analysis - fluorescence sampling tools - light collection tools - light measurement - flow cells - fluorovette - positive displacement pump - optical post mounts - reflection measurement tools - metrology - filter holder - mapping table - integrating sphere - reflectance standard - nanopositiioner - specular reflectance - absorbance standard - NIST - Raman standard - probe - cosine correction - radiometric standard -
|
|
|
|