Product Name: Cuvette Holder for 10-cm Cuvettes
Product Description
The CUV-UV-10 Cuvette Holder for 10-cm path length cuvettes couples via SMA-terminated
optical fibers to Ocean Optics high-sensitivity miniature fiber optic
spectrometers and light sources to create small-footprint spectrophotometric
systems for absorbance/transmission measurements of aqueous solutions and gases.
This compact cuvette holder is optimized for UV-VIS-NIR (~200 nm-2 µm)
applications.
CUV-ALL: $809
The CUV-UV-10 consists of these key components:
- Two adjustable 5-mm diameter f/2 quartz collimating lenses
- Cell compartment that accepts 10-cm cuvettes
- Built-in filter slot
- Manual light block for dark measurements
- Internal channels designed to accept a constant-temperature water source
(for heating and cooling of the base and cuvette, by means of convection)
- SMA 905 terminations for coupling to fiber optics.
- Each cuvette holder assembly comes with a black cover, which can be used
to eliminate ambient light.
Using the 10-cm cuvette holder is simple: Attach one SMA-terminated optical
fiber to one of the assembly's collimating lenses and another SMA-terminated
optical fiber to the assembly's other collimating lens. One of these fibers --
the illumination fiber -- is coupled to a fiber optic light source. The other
fiber -- the read fiber -- is coupled to the spectrometer. In some instances,
you may wish to adjust the collimating lenses for precise positioning of the
fiber at the lens focal point.
"Z" Dimension
All of the cuvettes and cuvette holders offered by Ocean Optics have a "Z"
dimension of 15 mm.
User's Tip
The collimating lenses common to each cuvette holder can be unscrewed from the
holder assembly and used separately in any fixture for applications that require
a fiber for free-beam coupling, such as on-line transmission or reflection.
Specifications
|
Pathlength: |
10 cm |
|
Collimating lenses (UV-VIS-NIR): |
»
Quartz lenses optimized from 200
nm-2 µm
»
5 mm diameter
»
f/2 |
|
Collimating lens termination: |
SMA 905 |
|
Filter slot: |
Accepts filters up to 1/4" (6 mm)
in thickness |
|
Base material: |
Aluminum |
|
Connections in base: |
Water inlet/outlet |
|
Water input fittings: |
1/8" NPT pipe thread |
|
Recommended optical fibers*: |
200 mm
illumination fiber; 50 mm
read fiber |
* There is no single combination of optical fibers that satisfies the
requirements of every application. As a rule, however, it is best to use a
large-diameter (>50 mm) illumination fiber to get maximum light throughput and a
small-diameter (<50 mm) read fiber to achieve the best optical resolution.
Company Details
Ocean Optics is a leading supplier of solutions for optical sensing – fundamental methods of measuring and interpreting the interaction of light with matter. We enable diverse applications in medical and biological research, environmental... more
| More Products of this Company: |
74-series Lens Fixtures, 84-series Lens Fixture, 84-series Lens Fixture, Absorbing Glass Optical Filters, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, Adjustable Collimating Lens Holder, Cell for Capillary Electrophoresis, CFV-series FluoroVettes, Cosine Correctors for Emission Collection, CUV-ALL-UV 4-way Cuvette Holder for 1-cm Cuvettes, CUV-UV Holder for 1-cm Cuvettes, CUV-VAR Variable Pathlength Cuvette Holder, CVD-UV and CVD-VIS Disposable Cuvettes, Diffuse Reflectance Standards, Electronic TTL Shutter, EviDot Semiconductor Nanocrystals, EviTag Water-stable Quantum Dots, FHS-UV In-Line Filter Holder, FHSA-series Filter and Cuvette Holder, FIA-SIA-LOV Sequential Injection Analysis System, Fiber Optic Scanning Monochromator, Fiber Optic Variable Attenuator, Flow Cell Kit for Flow Injection Analysis, Flow Cell Kit for Flow Injection Analysis, Fluorescence Flow Cell, Fluorescence Flow Cell, Fluorescence Flow Injection Analysis System, Fluorescence Standard, FOIS-1 Fiber Optic Integrating Sphere, FOS-2x2-TTL Inline Fiber Optic Shutter, Gershun Tube Kit, ISP-I Integrating Spheres, ISP-R Integrating Spheres for Reflectance, ISP-REF Integrating Sphere, ISS-2 Integrated Sampling System, ISS-UV-VIS Integrated Sampling System, Longpass Flow Cell, LTP-V Long Trace Profilometer, MPM-2000 Optical Multiplexer, Optical Post Mounts, Posts and Assemblies, Positive Displacement Pump, Power Supply & Controller for LEDs, Precision Optical Flats, Quartz Cells, Reflection and Transmission Stage, Right-angle Collimating Lens Holder, Right-angle Collimating Lens Holder, Shear-plate Collimation Testers, Single-point Reflection Stage, SpectroPipetter for Microliter-volume Samples, Specular Reflection Standard, Low Reflectivity, Specular Reflection Standards, High Reflectivity, Temperature-regulated Cuvette Holder and Kits, Thin Film Reference Wafer, Variable-angle Reflection Sampling System, Wireless-G Cable Gateway Cable Modem with Built-In Wireless-G Router, Wireless-N Broadband Router: Start a Wireless Network With Up To 4X the Range and 12X the Speed!, Wireless-N Gigabit Gaming Router: Build a high-speed wireless network optimized for gaming!, Wireless-N Gigabit Router with Storage Link: Start a Wireless Network With Up To 4X the Range and 12X the Speed!, Wireless-N Home Router: Start a Wireless Network With Up To 3X the Range and 9X the Speed! |
| Related Products: |
74-series Lens Fixtures, 84-series Lens Fixture, 84-series Lens Fixture, Absorbing Glass Optical Filters, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, ACH-CUV-VAR Adjustable Collimating Lens and Cuvette Holder, Adjustable Collimating Lens Holder, Broadband 200-1100 nm, CG-series Spectrometers, Cell for Capillary Electrophoresis, CFV-series FluoroVettes, CHEM4-UV-FIBER Spectrophotometer, CHEM4-UV-FIBER Spectrophotometer, CHEM4-UV-VIS Spectrophotometer, CHEM4-VIS-FIBER Spectrophotometer, CHEM4-VIS-FIBER Spectrophotometer, CHEM4-VIS-NIR Spectrophotometer, CHEMUSB4-UV-VIS Spectrophotometer, CHEMUSB4-VIS-NIR Spectrophotometer, Cosine Correctors for Emission Collection, CUV-ALL-UV 4-way Cuvette Holder for 1-cm Cuvettes, CUV-UV Holder for 1-cm Cuvettes, CUV-VAR Variable Pathlength Cuvette Holder, CVD-UV and CVD-VIS Disposable Cuvettes, Diffuse Reflectance Standards, Electronic TTL Shutter |
| Suitable For: |
light - spectrometer - spectrometers - Ocean Optics - sampling accessories - collimating lens - cuvette holder - cuvette - sampling systems for fluid analysis - fluorescence sampling tools - light collection tools - light measurement - flow cells - fluorovette - positive displacement pump - optical post mounts - reflection measurement tools - metrology - filter holder - mapping table - integrating sphere - reflectance standard - nanopositiioner - specular reflectance - absorbance standard - NIST - Raman standard - probe - cosine correction - radiometric standard -
|
|
|
|