Product Name: Alcatel-Lucent 1354 SN Submarine Management System (SMS)
Product Description
Overview
The Alcatel-Lucent 1354 SN is the network management solution for submarine customers, responsible for end-to-end configuration and monitoring submarine WDM optical paths. The user-friendly graphical user interface (GUI) provides graphical representation of the system and the managed elements, and assists the operator with specific procedures to equalize the quality of the WDM channels.
The 1354 SN allows you to take proactive steps to prevent problems before they occur, and provides the necessary tools to diagnose and repair the problems that do occur, thus improving the Quality of Service (QoS) you can offer your customers. The 1354 SN has the scalability to grow with your network -- both in size and technology -- and the flexibility to be customized to your organization's structure.
Benefits
Enhances usage of submarine network resources
Enhances submarine network reliability and availability
Facilitates and speeds-up network maintenance
Monitors the Quality of Service
Features
Fault management to supervise submarine WDM networks
Line supervision of the overall cable and line element (repeaters, branching units, submarine line terminal equipment)
Line fault location after detection of transmission failure
Performance monitoring
Automatic pre-emphasis adjustment to equalize the quality of the WDM channels
Power control system to assist operator in ramping up and shutting down the power feeding fo the cable system
Security policy customized according customer organization
Upstream external interfaces for integration with umbrella systems and downstream interface for managing EMS from others suppliers
High availability to provide the service continuity of the 1354 SN
Distribution for scalability
Documents
System (SMS) is the Alcatel network management solution for
submarine customers. The SMS allows corrective preventive actions to be carried
out during system life improving then the Quality of Service (QoS). The SMS has
the ability to evolve with traffic and technology and is adapted to customer’s
organization.
Network Management Objectives
Efficient and cost-effective operation in transport Wavelength
Division Multiplexing (WDM) technology based networks entails a need for
centralized and efficient network operation. Network Management facilitates the
operation and maintenance of ever growing networks in terms of size and
complexity by offering facilities which:
- Enhance usage of network resources;
- Enhance network reliability and availability;
- Facilitate and speed-up network maintenance;
- Monitor the Quality of Service (QoS).
The Submarine Management System
The SMS is the result of a seamless integration between the
1353SH and the 1354SN applications. The 1353SH is responsible for Network
Element (NE) installation, configuration and maintenance in the physical
submarine transmission network. The 1354SN is responsible for end-to-end
configuration and monitoring of submarine WDM optical paths. The SMS manages the
submarine networks composed of the following NEs:
- Tera10, OALW40, OALW16 Submarine Line Terminal Equipment (SLTE);
- Power Feeding Equipment (PFE);
- Submerged elements: repeaters, Tilt Equalizer unit (TEQ), WDM
Branching Unit (BU).
The SMS can be seamlessly integrated with Alcatel terrestrial
network management systems (co-hosting of functional and presentation parts).
The SMS can also be integrated in a multi-vendor architecture.
Graphical User Interface (GUI)
The SMS provides a user-friendly GUI based on animated graphical
views of the system and of the managed elements. The views are dynamic. The
color of an associated icon on a map or the presence of a symbol within an icon
reflects the status of each item. Navigation facility between SMS windows is
offered by means of edit or popup menus. Performance information can be
retrieved using filtering criteria and displayed in tabular or graphical format.
Both Zero Installation Client (ZIC) concept and Java based GUI over the Internet
are supported.
NE Representation
Once a NE is declared and configured, the operator can display
its representation in the SMS. A physical representation is available, tallying
with the real NE. Zooming into detailed equipment views is possible. Functional
views are also available such as Transmission view for an SLTE, which indicates
tributaries carrying traffic and protection tributaries.
Network Topology
Once the SMS is tailored and dimensioned to customer
requirements (configuration phase), a geographical view of the network is
available containing icons related to landing stations, BUs and sub-segments.
From this view, several other views can be accessed:
- Network Powering view;
- WDM view;
- Optical Path view;
- Line Equipment view;
- Transmission view.
Fault Management
All generic fault management facilities such as the alarm
acquisition, alarm counter management, current problem list management, alarm
log management are available to supervise submarine WDM networks.
Line Supervision
Line supervision activity can be carried out, for a list of Line
Elements (LE), on demand or periodically. In the latter case, a process called
Routine Maintenance (RM) is configured to request measurements of a list of LE
with a defined periodicity. A detailed report is provided at the end of the RM.
In both cases, LE measurements are displayed in real time and stored in a
database to be consulted later (history). Repeater power settings can be
adjusted after a cable repair or during system operation and maintenance.
Fault Location
After detection of a transmission fault or on operator request,
a fault location process is launched. Measurements collected during a fault
location are stored in a database. A detailed diagnosis is provided at the end
of the process and the report is stored. It includes the location and kind of
defect found:
- Localization of any transmission fault within a repeater
section.
- Discrimination of cable faults, fiber faults, optical
amplifier faults and transmission faults.
Performance Monitoring
Forward Error Correction (FEC) and SDH B1 counters can be
periodically (every 15 minutes and 24 hours) collected by the SMS at the WDM
channel level. A 1-day and 30-day Quality factor (Q factor), based on 24 hours
FEC counter processing are provided to the operator for each selected WDM
channel. Analog measurements, available on NE such as SLTE and PFE, can also be
collected on operator request or periodically (every 15 minutes and 24 hours).
Such information (FEC, Q factor and analog measurements) is stored in a database
and can be consulted at any time by the user.
Semi-Automatic Pre-emphasis Adjustment (APA)
The SMS provides facilities to assist the operator with this
specific procedure dedicated to equalize the quality of the WDM channels.
Power Control System (PCS)
The powering of a submarine WDM network is an operation which
has to be carefully carried out. So the SMS is able to assist the operator in
ramping up or shutting down the power feeding of the cable system and
configuring the BUs.
High Availability
To provide the service continuity of the network management
system, the SMS supports local and geographical High Availability facility based
on software mechanism or fault tolerant platforms.
Security
The availability of access control features in the SMS enables
the setting up of a security policy customized according to the cable operator
organization, so that each operator only uses the functions and resources that
are allowed and useful for its profile.
External Interfaces
In order to interface to external Operating Systems (OS),
supplied by Alcatel or other vendors, external interfaces were developed. These
interfaces are implemented withn Q3 standard and, with the aim of increasing the
openness of the interface, also through CORBA access (standard specified by the
Object Management Group) via TCP/IP. These interfaces are compliant with TMF and
ITU standards.
System Characteristics
- Hardware components: the SMS is available on Hewlett-Packard’s
workstation or servers, and on PC (GUI only);
- Software components: the SMS is built on a generic software
platform. The software platform consists of both Alcatel software modules and
first rank international companies.
References
The SMS is supplied on several tens of projects such as
Sea-Me-We3, Gemini, Japan-US, Southern Cross and Flag projects.
Company Details
Formed from the merger of Alcatel and Lucent Technologies, Alcatel-Lucent combines two entities that share a common lineage that can be traced back to 1986, when Alcatel’s parent company, CGE (la Compagnie Générale d’Electricité), acquired ITT’s... more
| More Products of this Company: |
Alcatel-Lucent 1620 Light Manager, Alcatel-Lucent 1621 Link Extender, Alcatel-Lucent Branching Unit for Optical Fiber Submarine Cable System, Alcatel-Lucent OAL Repeaters for Submarine Systems, Alcatel-Lucent Submarine PFE Power Feed Equipment, Alcatel-Lucent URC2 Unrepeatered Fiber Optic Cable 2 |
| Related Products: |
Alcatel-Lucent 1620 Light Manager, Alcatel-Lucent 1621 Link Extender, Alcatel-Lucent 7385 Wireless IP Antenna Unit - Radio Equipment, Alcatel-Lucent 7385 Wireless IP Digital Base Station, Alcatel-Lucent 7385 Wireless IP Subscriber Unit-Network Termination, Alcatel-Lucent 7385 Wireless IP Subscriber Unit-Radio Termination, Alcatel-Lucent 9400 AWY Digital Microwave Radio Links, Alcatel-Lucent 9400 LX Digital Microwave Radio Links, Alcatel-Lucent 9400 UX Digital Microwave Radio Links, Alcatel-Lucent 9500 Microwave Cross Connect, Alcatel-Lucent 9500 Microwave Cross Connect, Alcatel-Lucent 9600 LSY Long-Haul Digital Radio Links, Alcatel-Lucent 9600 USY SDH Urban Digital Radio Links, Alcatel-Lucent Branching Unit for Optical Fiber Submarine Cable System, Alcatel-Lucent MDR-8000 & MDR-8000s Low-to-High Capacity Microwave Digital Radio, Alcatel-Lucent MDR-8000 Compact Low Profile Shelf, Alcatel-Lucent MDR-8000 Lite Low-Profile Unlicensed Radio, Alcatel-Lucent OAL Repeaters for Submarine Systems, Alcatel-Lucent Submarine PFE Power Feed Equipment, Alcatel-Lucent TSM-2532 Fault Management System, Alcatel-Lucent TSM-8000 Fault Management System, Alcatel-Lucent URC2 Unrepeatered Fiber Optic Cable 2, Burst A/D MUX PSRAM, CellularRAM, CMOS Imaging Technical and Customer Service Notes |
|