Stinger® LS+/LS DSL Access Concentrators  
Search Country   Reset filter

Stinger® LS+/LS DSL Access Concentrators

Product Name: Stinger® LS+/LS DSL Access Concentrators

Product Description

The high-density, mid-sized Stinger® LS+/LS DSL Access Concentrator has a flexible IP/ATM architecture built for scalability and throughput, and provides integrated support for IP switching and routing and multicasting – enabling high-performance video and multimedia services.

An excellent choice for deployment in small central offices and multi-dwelling buildings, the Stinger® LS+ supports up to 648 ports in a 19-inch rack. The Stinger® LS offers two models, which support up to 360 DSL ports in a 19-inch rack and 504 ports in a 23-inch rack.

Benefits

The Stinger® LS+/LS opens up new multimedia revenue opportunities while helping service providers minimize costs.
Take advantage of combined IP and ATM capabilities to deliver a broad spectrum of high-value multimedia services
Gain the reliability of high-speed switching, backed by Quality of Service (QoS) capabilities
Expand and upgrade easily via a modular design and subtending capabilities
Migrate seamlessly to next-generation packet networks
Minimize costs with a high-density design that allows incremental implementation of new technologies 
Integrate seamlessly with existing networks

Features

The Stinger® LS+/LS offers a flexible, high-density design for cost-effective support of new multimedia services. 

Reliable high-performance ATM switching and IP routing 
Up to 4 Gbps data throughput to support today's advanced multimedia services
ATM QoS capabilities to enable a broad range of premium services backed by Service Level Agreements (SLAs)
Redundant control modules and trunk ports (1:1) with automatic fail-over
IP multicast for broadcast audio/video, video-on-demand 

High port density to maximize capacity in co-location environments 
Up to 648 ports in a 19-inch rack, with Stinger® LS+
Up to 360 ports in a 19-inch rack, with Stinger® LS, Model 1
Up to 504 ports in a 23-inch rack, with Stinger® LS, Model 2

Flexible, modular architecture for cost-effective expansion, upgrades and migration 
Expandable configuration
Support for a mixture of interfaces and DSL types
Easily exchangeable modular components that provide an upgrade path
Subtending capabilities

Technical Details

Stinger® LS+/LS DSL Access Concentrator 

Electrical Specifications 

Power requirements: 

–48 VDC @ 1,100 Watts maximum

Inrush 

All modules have inrush limiting circuits

Power connectors 

Two #8 studs per input

Physical Specifications 

Overall chassis size 

Stinger LS+ Model: 24.5 in. (62.2 cm or 14U) high x 17 in. (43.2 cm) wide x 10 in. (25.4 cm) deep. Fits in 19 inch rack

Unit weight (fully configured): 

Stinger LS+ Model: 120 lb (55 kg) maximum

Card Slots 

Stinger LS+ Model: 

9 for line interface protection modules (LIPMs)

1 of the 9 slots can be used for a line interface module (LIM)

1 for line protection modules (LPMs)

2 for control modules (CMs)

2 for trunk modules (TMs)

Line Interface 

50-pin RJ-21X (3 per LIPM and 2 or 3 on LPM in LPM slot)

Trunk Interfaces 

OC-3c/STM-1 optical: single-mode or multimode

DS3/E3 electrical with pass through

T1/E1

Gigabit Ethernet with IP2100/IP2000: optical or copper

Operating Environment 

Ambient operating temperature: 

32ºF to 131ºF (0ºC to 55ºC)

Relative humidity: 

10% to 95% (non-condensing)

Operating altitude: 

Up to 13,123 ft (4,000 m)

Certification 

Telcordia GR-63-CORE (NEBS level 1-3)

Telcordia GR-1089-CORE

EN/IEC 60950

Electromagnetic compliance 

FCC Part 15 Class A

EN 55022 Class A

AS/NZS 3548 Class A

VCCI Class A

CISPR 22 Class A

EN 300386-2

Model Numbers 

STGRLS-1 Unit: 

Stinger LS Model 1 Base Unit

STGRLS-2 Unit: 

Stinger LS Model 2 Base Unit

STGRLR-WMB: 

Wall mount bracket





Stinger® LS DSL Access Concentrator 

Electrical Specifications 

Power requirements: 

–48 VDC @ 1,100 Watts maximum

Inrush 

All modules have inrush limiting circuits

Power connectors 

Two #8 studs per input

Physical Specifications 

Overall chassis size 

Stinger LS Model 1: 24.5 in. (62.2 cm or 14U) high x 17 in. (43.2 cm) wide x 10 in. (25.4 cm) deep. Fits in 19 inch rack

Stinger LS Model 2: 24.5 in. (62.2 cm or 14U) high x 21.3 in. (54 cm) wide x 10 in. (25.4 cm) deep. Fits in 23 inch rack

Both are equipped with rack mounting ears

Unit weight (fully configured): 

Stinger LS Model 1: 120 lb (55 kg) maximum

Stinger LS Model 2: 145 lb (66 kg) maximum

Card Slots 

Stinger LS Model 1: 

5 for line interface modules (LIMs)

2 for control modules (CMs)

5 for line protection modules (LPMs), path selector modules (PSMs), and/or Copper Loop Test (CLT) modules

2 for trunk modules (TMs)

Stinger LS Model 2: 

7 for line interface modules (LIMs)

2 for control modules (CMs)

7 for line protection modules (LPMs), path selector modules (PSMs), and/or copper loop test (CLT) modules

2 for trunk modules (TMs)

Line Interface 

50-pin RJ-21X 21X (2 or 3 per LPM depending on LIM used)

Trunk Interfaces 

OC-3c/STM-1 optical: single-mode or multimode

DS3/E3 electrical with pass through

T1/E1

Gigabit Ethernet with IP2100/IP2000: optical or copper

Operating Environment 

Ambient operating temperature: 

32ºF to 131ºF (0ºC to 55ºC)

Relative humidity: 

10% to 95% (non-condensing)

Operating altitude: 

Up to 13,123 ft (4,000 m)

Certification 

Telcordia GR-63-CORE (NEBS level 1-3)

Telcordia GR-1089-CORE

EN/IEC 60950

Electromagnetic compliance 

FCC Part 15 Class A

EN 55022 Class A

AS/NZS 3548 Class A

VCCI Class A

CISPR 22 Class A

EN 300386-2

Model Numbers 

STGRLS-1 Unit: 

Stinger LS Model 1 Base Unit

STGRLS-2 Unit: 

Stinger LS Model 2 Base Unit

STGRLR-WMB: 

Wall mount bracket

Documents

Applications

• Provide cost-effective service to remote outdoor areas or smaller indoor facilities, like Multi-Dwelling Units (MDUs) and businesses in a campus environment

• Extend the DSL reach and capacity of existing Stinger® Access Systems, using the hosted platform

• Deliver Gigabit Ethernet capabilities cost-effectively, using the standalone platform with the Stinger® IP2000 control module

Features

Efficient compact design – Includes power, cooling, ventilation, protector block, cabling and thermal conditioning, with space available for a remote test set

Environmentally hardened enclosure – Enables outdoor deployment in a wide variety of locations

Thermal arrangement options – Meets known requirements for all types and combinations of DSL

Flexible mounting capabilities – Includes OSP cabinet/wall, pole and pedestal/pad mounting options which feature “add-on” field replacable mounting hardware requiring no new additional real estate.

Interoperable LIM cards – Enables the use of the same Stinger® Line Interface Module (LIM) cards used throughout the Stinger® portfolio

Gigabit Ethernet Support* – Using the Stinger® IP2000 control module, the Stinger® DSL Access Concentrator Compact Remote enables lucrative IP-based services, such as video and streaming multimedia

15-km Fiber Span** – The hosted platform uses an optical connection to a larger Stinger® controller and aggregation node and extends high-speed DSL services closer to subscribers.

Three-slot Capacity** – A single remote unit can support up to 144 ports, in increments of 48 ports.

Host Capacity** – A Stinger® host platform can support up to 6 Stinger® DSL Access Concentrator Compact Remotes per LIM slot. That enables a maximum of 8 Compact Remotes hosted by one Stinger® FS+, with up to 4156 ADSL ports.

Benefits

Expanded revenue opportunity – Provide the high-value broadband services subscribers demand— including video, streaming media and interactive gaming—in a wider range of locations

Reduced expansion costs – Increase the capacity of existing Stinger® systems with the cost-effective hosted platform

Extended network reach – Gain additional income from underserved subscribers in remote areas and smaller facilities, while keeping costs down

Competitive edge – Deliver advanced services supported by today’s highest speed DSL or Gigabit Ethernet technology

Streamlined deployment – Simplify deployment of new services with a compact remote unit that’s easy to install in nearly any indoor or outdoor location

Technical Specifications

1.Electrical Specifications

Power requirements: 3, 4, or 5 ± 190 VDC, RFT-V input pairs; pairs are 100va limited and GFI protected Power Consumption: One complete system (chassis, cooling fan module, control and optics pack, power supply, and three 48 port LIM/LPM pairs) in an outdoor chassis with protector blocks and cabling: 260 watts maximum

2.Physical Specifications Overall chassis size: 30.1 in (766 cm) high x 16.2 in (412 cm) wide x 11.5 in (292 cm) deep Outdoor Enclosure size: 40.5 in (1029 cm) high x 20.5 in (520 cm) wide x 12.6 in (320 cm) deep Unit Weight (with fans, power supply, protector blocks, and cables): 121 lbs. (54.885kg.) maximum Mounting options: Several mounting kits are available for cabinet, pole and pedestal applications.

3.Card slot

3 for remote line interface modules (RLIM)

3 for line protection modules (LPM)

1 for controller

4.Trunk Physical Interfaces

SONET-like, OC3c-like, single-mode

Optical (Hosted version)

Gig E , T1 IMA (Standalone Versions)

5.Line Interfaces

Three 64-pin (96 pairs, total) connectors on each LPM, 48 pairs for connection to PSTN, 48 pairs for combined ADSL/POTS to subscribers

6.Other Hardware Interfaces

One RJ-11 jack on each LPM for test access

One DB9 RS232 on COP or CM diagnostic and operations port

One DB15 on COP or CM for 7 miscellaneous alarm inputs

Power connection: wire stubs

7.Status Indicators

Port Status – Control & Optical Pack,

4 Activity Indicator LEDs

Trunk status – On & Activity Indicators – 5 indicator LEDs per LIM

Cooling Unit Status – 2 Activity Indicator LEDs, Internal and External

8.Operating Environment

Operating temperature: -40°C to 46°C (-40°F to 114.8 °F) Relative humidity:

10% – 95% (non-condensing) Operating altitude: up to 13,123 ft (4,000 m)

9.Protocol Specifications

ATM Forum UNI (v3.0 and v3.1)

ATM Forum Traffic Management (v4.0)

10.Certification

Telcordia GR-1089-CORE

11.Electromagnetic Compatibility

FCC Part 15 Class A; ICES003 Class A

12.Safety

UL/cUL Listed to UL 60950-1, 60950-21;

CSA C22.2 No. 60950-1, No. 60950-21

13.ADSL Interface Standards

ANSI T1.413-1998 (ADSL); ITU-T G.992.1

(ADSL); ITU-T G.992.2 (ADSL-lite);

ITU-T G.992.3 (ADSL2); ITU-T G.992.4

(ADSL2-lite); ITU-T G.992.5 (ADSL2+);

ITU-T G.994.1 (G.hs); ITU-T G.997.1

(physical layer management)

14.OC3c/STM-1 Interface Standards

(Hosted version)

SONET-like, OC-3c-like: GR-253-CORE, ITU-T G.804, ITU-T I.432, ATM Forum UNI (v3.0 and v3.1)

15.Optical Specifications

(Hosted version)

155.52 Mbps; Single mode laser optics; Nominal wavelength: 1310 nm; Loss budget: 10 dB for intermediate reach per Telcordia GR-253

16.Model Numbers

STGRCR-UNIT: (Hosted Version)

STGRSACR-MODEL (Standalone Version): Stinger® DSL Access Concentrator Compact Remote complete chassis model with shelf assembly, backplane, cooling module, cabinet, fiber management tray, protector blocks and mounting STGRCR-LIM-AP-48: 48 port ADSL2+ capable Line Interface Module for the Stinger® DSL Access Concentrator Compact Remote specifically designed for short reach and low power applications STGRCR-LPM2-48-S: 48 port Line Protection Module with built-in splitters for use with the Stinger® DSL Access Concentrator Compact Remote, Stinger® RT and Stinger® LS STGRCR-COP-OC3: Control and optics pack for use with the hosted version of the Stinger® DSL Access Concentrator Compact Remote

Company Details

Formed from the merger of Alcatel and Lucent Technologies, Alcatel-Lucent combines two entities that share a common lineage that can be traced back to 1986, when Alcatel’s parent company, CGE (la Compagnie Générale d’Electricité), acquired ITT’s... more

More Products of this Company: Alcatel-Lucent 7300 Advanced Services Access Manager (ASAM) -- ANSI Version, Alcatel-Lucent 7300 Advanced Services Access Manager (ASAM) -- ETSI Version, Alcatel-Lucent 7300 Advanced Services Access Manager -- compact unit, Alcatel-Lucent 7300 Advanced Services Access Manager Outdoor Cabinet, Alcatel-Lucent 7301 Advanced Services Access Manager (ASAM) -- ETSI Version, Alcatel-Lucent 7302 Intelligent Services Access Manager, Alcatel-Lucent 7321 Remote Unit Enhanced Density, Alcatel-Lucent 7324 Remote Unit, ISAM Voice Package, Stinger® Compact Remote DSL Access Concentrator, Stinger® FS+ DSL Access Concentrator, Stinger® IP2100/IP2000 Control Module, Stinger® MRT DSL Access Concentrator, Stinger® MS+ DSL Access Concentrator, Stinger® RT DSL Access Concentrator
Related Products: Alcatel-Lucent 1000 Line Gateway, Alcatel-Lucent 1350 Management Suite, Alcatel-Lucent 1353 Network Manager, Alcatel-Lucent 1354 SN Submarine Management System (SMS), Alcatel-Lucent 1512 SHDSL, Alcatel-Lucent 1521 Copper Line IP, Alcatel-Lucent 1521 Fiber optical Line systems, Alcatel-Lucent 1531 Copper Line Access Switch, Alcatel-Lucent 1540 Litespan Multiservice Access Gateway, Alcatel-Lucent 1620 Light Manager, Alcatel-Lucent 1626 Light Manager, Alcatel-Lucent 1640 Optical Add/Drop Multiplexer (80/160 channel DWDM System), Alcatel-Lucent 1642 Edge Multiplexer, Alcatel-Lucent 1642 Edge Multiplexer Compact, Alcatel-Lucent 1650 SMC STM1/4 Multiservice Metro Node, Alcatel-Lucent 1660 SM STM-16/64 Optical Multi-Service Node for Metro Applications, Alcatel-Lucent 1660 SM STM-16/64 Optical Multi-Service Node for Metro Applications, Alcatel-Lucent 1662 SMC STM-4/16 Compact Multiservice Node for Metro Networks, Alcatel-Lucent 5523 ADSL Work Station, Alcatel-Lucent 5526 Access Management System, Alcatel-Lucent 5528 Web-based Access Manager (WAM), Alcatel-Lucent 5530 Network Analyzer, Alcatel-Lucent 5539 Statistics and Data Collector, Alcatel-Lucent 5549 Access Provisioning Center, Alcatel-Lucent 7300 Advanced Services Access Manager (ASAM) -- ANSI Version
Home | Members.Benefit | Privacy.Policy | Bookmark.This.Page | Contact.Us
© 2006 - 2007 4engr. All Rights reserved |Recommended Engineering Sites:| Center for Respect of Life and Environment | Internet Dictionary|Enginering intent(Engineering Events) | Map Archive