| Aircontrol Technologies' Filtration Laboratory |
|
|
|
In addition to supporting CONPAR production in clean room conditions, Aircontrol Technologies' filtration laboratory offers services for assessing particulate contamination in aviation fuel samples to IP216 and ASTM D2276 standards.
Samples sent... more |
|
|
| Consumable Items |
|
|
|
Aircontrol Technologies offers a complete range of replacement consumable items and spares for the CONPAR System.
Items including replacement field monitors, specimen slides, mountant solution and filter membranes can be supplied together with... more |
| Ancillary Equipment |
|
|
|
A wide range of ancillary equipment is available to compliment and extend the CONPAR system.
Equipment includes the Static Sampler for use with reservoirs, barrels, etc. where system pressure is unavailable. Sampling Control Valves for use... more |
| Master Slides |
|
|
|
Calibrated Master Slides representing the contamination classes of NAS1638 Classes 4 to 12 and DEF STAN 05-42 Classes 400 to 100,000 are available.
Each Master Slide comprises a filter membrane mounted between two pices of high optical quality... more |
| Particle Comparison Set |
|
|
|
This includes the CONPARSCOPE, a purpose designed field microscope with movable stage and its own light source. The set also includes the consumable items required to mount the samples for analysis.
Sets are available for 220V and 110V power... more |
| Field Fluid Sampling Set |
|
|
|
The Field Fluid Sampling Set comprises the sampling unit and associated valves and consumable items required for taking dynamic samples. All equipment is designed to be self-cleaning and will not add or subtract contamination from the sample.
... more |
| Odour Adsorption Filters |
|
|
|
Cabin air quality is important to passenger comfort. Aircontrol Technologies uses advanced activated carbon technology to remove odours and volatile organic compounds (VOC's). Combining odour removal with high efficiency particulate filtration media,... more |
| Helicopter Gearbox Oil Cooling |
|
|
|
With gearboxes for the main rota and tail rota and no forced air cooling, helicopters have a unique requirement for engine oil and gearbox oil cooling systems. Airscrew has developed complete systems for helicopters with the supply of the mechanical fan... more |
| EH-101 Avionics Cooling |
|
|
|
The demands for special cooling of modern electronics is critical when applied to airborne equipment with added emphasis on noise, compactness and weight. Airscrew can design and build optimised avionics cooling systems an example of which is the EH101... more |
| Sea King Searchwater Radar |
|
|
|
Aircontrol Technologies Airborne Vapour Cycle System provides conditioned recirculated air to the radar of the Sea King Airborne Early Warning Helicopter. A second evaporator circuit also provides spot cooling for the radar operators.... more |
| Temperature Transducers |
|
|
|
Temperature Sensing Range: -70oC - +250oC
Hysteresis: 106 Cycles
Power Supply: 16V - 32V DC
Output: voltage or frequency
Typical Applications: Tiger Gearbox Oil Temperature... more |
| Temperature Switches |
|
|
|
Temperature Sensing Range: -70oC - +250oC
Hysteresis: selectable up to 25% set range
Ambient Temperature Range: -70oC - +250oC
Operational Life: >106 Cycles
Power Supply: 16V - 32V DC
Output: 2A -5A resistive or inductive... more |
| Temperature Sensors |
|
|
|
Temperature Sensing Range: -70oC - +250oC
Ambient Temperature Range: -70oC - +250oC
Operational Life: >106 Cycles
Power Supply: 16V - 32V DC
Output: resistance change to BS1904 typically
Typical Applications: Eurofighter... more |
| Pressure Switches & Sensors |
|
|
|
Pressure Range: 0 - 300 bar
Over Pressure: >2X Pressure Range
Operating Temperature: -55oC - +250oC
Operational Life: >106 Cycles
Power Supply: 16V - 32V DC
Output: Sensors 0 - 10V DC
Switches 2A -5A resistive or inductive... more |
| Odour Adsorption Filters |
|
|
|
Cabin air quality is important to passenger comfort. Aircontrol Technologies uses advanced activated carbon technology to remove odours and volatile organic compounds (VOC's). Combining odour removal with high efficiency particulate filtration media,... more |
| Fluid Filters |
|
|
|
Aircontrol Technologies designs and manufactures filters for use in fluid systems where contamination control is critical. Using metallic and non-metallic filtration media, the company designs filters to suit customer' specific requirements ranging from... more |
| Eurofighter Typhoon Crew Temperature Control |
|
|
|
Aircontrol Technologies has designed and supply the Liquid Conditioning Generating Unit (LCGU) and the Liquid Suit Connector Assembly (LSCA).
The LCGU houses the main components of the system, providing the fluid flow and allowing for changes... more |
| Generators |
|
|
|
Drive: Mechanical or Hydraulic
Output Range: 5kva-10kva
Typical Applications: Emergency Power Generation for 146/RJ, Gulfstream IV and V, B757 and B767
... more |
| AC Induction Motors |
|
|
|
Supply Voltage: 115V - 200V, 1ph and 3ph, 400Hz fixed and wild frequency
Output Power Range: 120W to 6kW
Typical Applications: Wheel Brake Cooling, Galley Oven Fan Drives, Hydraulic Pump Drives
... more |
| DC Brushless Motors |
|
|
|
Supply Voltage: 18V - 32V DC and 270V DC Aircraft Supply
Output Power Range: 5W - 2kW typical
Typical Applications: Eurofighter Wheel Brake Cooling, B757,747,777,Galley Ovens and 146/RJ Wheel Brake Cooling
... more |