| Miner's Support System and Multipurpose Pouch |
|
|
|
Applications
Construction
Mining
Hazards
Confined Space
Product Information
A lightweight... more |
|
|
| Escort® ELF Sampling Pump |
|
|
|
Principles of Operation
The state-of-the-art
electronic laminar flow sensor, consisting of a laminar flow element and
pressure sensor, provides constant flow (volume)... more |
| Comfo-Cap® Protective Headwear |
|
|
|
Principles of Operation
Not applicable
Approvals & Standards
Meets... more |
| Kwik-Draw® Detector Tube Pumps |
|
|
|
Principles of Operation
Kwik-Draw detector tube pumps are designed for one-handed operation and
consistent delivery of a sample volume of 100 milliliters (ml). An integral
counter helps track the number of sample... more |
| Detector Tubes and Pumps |
|
|
|
Applications
Agriculture
Chemical
Construction
Domestic Preparedness
Electric Utility
Fire Fighting
Hazardous Materials
Mining
Nuclear
Oil and Gas
Paper & Pulp
... more |
| W65 Self-Rescuer Respirator |
|
|
|
Approvals & Standards
Approved by the Mine Safety and Health Administration (MSHA) and the National
Institute of Occupational Safety and Health (NIOSH) (Approval No. TC-14G-82) for
self-rescue from carbon monoxide... more |
| SafeTOX® and SafeVOC® Gas Monitors |
|
|
|
Applications
Agriculture
Chemical
Construction
Electric Utility
Gas Detection
General Industry
Hazardous Materials
Manufacturing
Medical
Mining
Oil and Gas
Paper &... more |
| Solaris® Multigas Detector |
|
|
|
Approvals & Standards
UL, CUL, CSA, ATEX, Australia/New Zealand and MSHA approved.
Applications
Chemical
Construction
Electric Utility
Fire Fighting
Gas... more |
| Ultima® X Series Gas Monitors with X3® Technology |
|
|
|
Principles of Operation
Catalytic, electrochemical and
infrared gas detection methods.
Approvals & Standards
... more |
| Ultima® X Series Gas Monitors |
|
|
|
Principles of Operation
Advance sensing technologies monitor against the threat of combustible and toxic
gases and for oxygen deficiency, utilizing catalytic, electrochemical and
infrared gas detection methods.
... more |
| TRITIUM ON SURFACE |
Radio System |
|
|
System: Electret Ion Chamber
Lab/Field: Field ( Surface contamination measurements)
Radiation detected : Low energy beta radiation from tritium, C-14, or from Tc-99
Operation
This system is a passive integrating detector... more |
| TRITIUM IN AIR |
Radio System |
|
|
System: Electret Ion Chamber
Lab/Field: Field (In situ measurements)
Radiation detected : Airborne tritium
Operation
This system is a passive integrating detector for field measurement of airborne tritium. It consists... more |
| TRITIUM CONTAMINATION IN PIPES TOOLS and OBJECTS |
Radio System |
|
|
System: Ion Transfer Electret Ion Chamber
Lab/Field: Field (In situ measurement )
Radiation detected : Low energy beta emitters such as tritium inside pipes, on contaminated tools and other irregularly shaped objects.
Introduction
... more |
| Radon in Water |
Radio System |
|
|
Significance
Subsoil radon is in intimate contact with the well water and carries some dissolved radon. When water is used in homes for shower, in laundry or other purposes, radon gets released from water and spreads into room air. EPA estimates... more |
| Radon Flux from Mill Tailings, Phosphate Stacks & Ground |
Radio System |
|
|
System: Electret Ion Chamber
Lab/Field: Field (In situ measurement )
Radiation detected : Radon flux from ground, phosphate stacks, uranium mill tailings
Introduction
The passive measurement of radon flux from the... more |
| Plutonium and Uranium in Soil |
Radio System |
|
|
System: Electret Ion Chamber
Lab/Field: Field (In situ measurement on soils)
Radiation detected: Alpha
Operation
This system is a passive integrating detector for measurement of alpha-emitting contaminants in soils... more |
| LOW ENERGY XRAYS mammography air scatter skyshine video terminal |
Radio System |
|
|
System: Ultra low energy thin window (7 mg cm2 ) X ray measuring Electret Ion Chamber for measuring mammography X rays, medical X rays, Sky shine or air scatter X rays and video terminal emitted X rays
Lab/Field: Field (In situ measurement )
... more |
| ENVIRONMENTAL AND WORK PLACE GAMMA RADIATION |
Radio System |
|
|
System: Electret Ion Chamber
Lab/Field: Field (In situ measurements)
Radiation detected: Gamma Radiation
Operation
This system is a passive integrating detector system for field measurement of X or gamma radiation... more |
| Custome Electret material made from FEP Teflon |
Radio System |
|
|
Custom Prepared To meet your requirement at economical price
Uses:
For air cleaning in small inaccessible places such as CD players PC hard disks etc.,
For miniature microphones, electret speakers,
For radon and radiation detectors
... more |
| ALPHA SURFACE CONTAMINATION |
Radio System |
|
|
System: Electret Ion Chamber
Surfaces contaminated with alpha activity
Radiation detected : Alpha
Operation
This system is a passive integrating detector system for measurement of alpha-emitting contaminants on surfaces... more |