CE2000 General Control Software  

Details on CE2000 General Control Software



        

CE2000 General Control Software

Features

  • Allows digital controllers and filters to be graphically developed and then run with simulated virtual or real-time systems
  • Easy & logical to use icon based, menu driven, drag and drop format
  • Comprehensive library of control and instrumentation blocks including standard controller / filter configurations
  • Connects to the real world using analogue to digital / digital to analogue interface
  • Ideal for use at all training and academic levels as well as for
    research / industrial development applications
  • Supported by a comprehensive technical, theoretical and applications based user guide / text book
  • Supports current practices and techniques used in the control and process industries
  • Compatible with existing TecQuipment Control products

And many moreÖ!

CE2000 is a Windows software package offering many powerful features to allow students and experienced control engineers, to develop and test a wide selection of controller and filter configurations and strategies.

With CE2000 controller design and implementation are part of the same logical process, significantly reducing the learning difficulties a student may have while speeding up the time it takes to actually achieve a fully working controller configuration.

CE2000 is fully compatible with the existing range of control engineering models available from TecQuipment which exhibit a wide selection of system responses, including: linear/non-linear, stable/unstable, oscillatory, multi-variable.

With CE2000 it is possible to not only model one or more possible controller solutions but also to simulate their theoretical responses and/or investigate their actual responses with physical systems.

Because of its open and flexible structure CE2000 and its associated interface devices may also be used to model, simulate and run any compatible system.

Hardware Requirements

CE2000 software is supplied on 3.5" diskette with a comprehensive operating/technical/applications manual which includes a library of controller and filter configurations as standard.

The CE2000 software will run on a 386 based IBM compatible PC with 387 co-processor, Windows 3.1 or above (including Windows '95) installed and 4Mb of ram. However the recommended minimum configuration is a 486DX with 8Mb of ram.

Circuits can be designed and edited and data files reviewed at any time. For real time control or simulation one of TecQuipment's computer interfaces is required: either the CE120 Controller or the CE122 Digital Interface

 

CE2000 is used in much the same way as you would traditionally develop a control system on a sheet of paper or on a chalkboard.

Traditional Method CE2000

Draw the circuit elements in block form in the required position. These may include proportional/differentiating/integrating amplifiers, signal generators, power supplies, instrumentation, etc.

Drag and drop the required circuit elements from the comprehensive library of standard or customised blocks available on screen.

Link the blocks together with lines, with arrows indicating the flow of signals, to produce the system required.

Connect the blocks together as required using the wiring tool/soldering iron cursor. In a similar way to using a soldering iron to build a real electronic circuit.

Re-draw the diagram as many times as required until the desired circuit is produced.

Re-position the icon blocks and change the wiring as required.

Estimate the gains and settings of each of the blocks to achieve the required performance.

Set the estimated gains and settings of each of the blocks to achieve the desired system performance.

Use another medium eg: hardware and/or software to create and test the proposed design.

Press the 'Play' button to run the circuit to test the design and make adjustments to maximise performance as required.

Any mistakes may mean starting again.

Save the test results and circuit configuration to recall later and obtain a hard copy of graphed system responses.

 

 

Category:
Type:
Related companies: Mike Pritchard, Speer Canada Inc., United Composites B.V., NetComposites, Robinson Fans Florida, Inc., Yeung's Fiberglass, RAM Universal Limited, VISTAGY, Inc., Australian Composite Structures Society, European Composites Industry Association, Therm-Omega-Tech, Inc., Airtech International, Inc., MATERIAL, Watts Regulator Company, Rossvalve, TAP Plastics, Ashe Controls Ltd, Arrowquint Ltd, Aztech Machinery Inc, status-automation.com, controlvalves.com, Infrared Training Center, CELLULOSE CONVERTING EQUIPMENT Srl, Cable Glands India, Avery PrintandMailCenter.com
Related products: High-Performance Plastics, Aircraft Wing, Abradable Seals, Acoustic Media, Sport & Leisure, Transportation, Talon Chair, Air Foil, Axial Flow, Backwardly Inclined, FORWARD CURVE, Industrial Dampers, Industrial Exhausters (IE), Paddle Wheel (PW), Radial Blade, Towpregs, Fiber creels, V-port Control Valve, Fugitive Emission Control, RAM SEAL, valve actuation., Richter, Butterfly valves, Dia-Flo, Valve Position Monitoring
Related researches: FLOW-STRUCTURE INTERACTION, BIOMECHANICS, MECHATRONICS/ROBOTICS, VIBRATION AND NOISE, Flying on Hydrogen: Georgia Tech Researchers Use Fuel Cells to Power Unmanned Aerial Vehicle, Compute-intensive applications : The new Cell Accelerator Board, New fuel cell design adds control, reduces complexity, Robotics and Control, The HITRAN 2004 molecular spectroscopic database : Matter in the gas phase interacts, Scientists Find High Energy Systems Hidden in 'Gas Cocoon', The largest fusion experiments in the world : cutting edge of plasma physics., Resolves Einstein’s Twin Paradox : LSU Professor, Container protecting & navigating robots by sensing network, Disorder May Be in Order for ‘Spintronic’ Devices, Flow specially of tiny bubbles specially microfluidic device mimics computer circuitry, FINDING SURVIVORS, PROTECTING DRIVERS, Full-wave rectifier uses current-feedback amps, High Speed Transfer Control layer Protocol development, Computing and Monitoring System for Discovery BY UCoMS, Satellites to take off with less fuel : Developed By Georgia Tech researchers, PID Controller, Radiation Therapy for Cancer Patients Controlled & Could Speed Up by Machine Learning, Angle-Resolved Photoelectron Spectroscopy, Detect cancer and neurological diseases by identifying certain molecules present in human blood or urine, Taming Stem Cells
Related press releases: New design could open door to small-scale fuel cells, Muscle work replaced by Robotic exoskeleton, Next generation machine : 20 miles long & $6.7 Billion, 80-Core Processor : Intel NewTests Chip, Recommendation for capture and control of Hexavalent Chromium (Cr(VI)) dust/fumes in chromium catalyst pigment production released by United Air Specialists
Home | Members.Benefit | Privacy.Policy | Bookmark.This.Page | Contact.Us
Conveyor technology | Microscopes | IT jobs

© 2006 - 2009 Engineering Information. All Rights reserved.